background image

Foot Dispenser

Item # 98050

With Vacuum

ASHCROFT

MADE IN U.S.A.

60

90

100

80

70

psi

0

10

20

40

50

30

2

1

3

4

6

5

1

ASHCROFT

100

90

80

70

60

MADE IN U.S.A.

psi

0

10

20

40

50

30

7

EQUIPMENT

Instruction Sheet

Loctite

®

Foot Dispenser with Vacuum

Part No. 98050

SET UP AND OPERATION

1. Connect Foot Dispenser (1/8 NPT connection) to a 100 PSI

maximum dry filtered air supply.

2. Insert quick connect end of 10cc or 30cc Airline Adapter 

into air outlet port of the Foot Dispenser and turn clockwise
until secure.

3. Turn Regulator knob on the end of the Foot Dispenser

clockwise to increase dispense pressure. Pressure Gauge
will indicate desired pressure setting.

4. If vacuum “Suck-Back” is desired, turn Vacuum Adjustment

Knob counterclockwise to increase vacuum intensity.

CAUTION: Excessive vacuum could draw material into the air
line. Use only enough vacuum to draw back material into the
dispense tip.

5. To activate dispense circuit, press on Foot Dispenser pedal.

Material should flow as long as the pedal is depressed.

6. The amount of material dispensed per cycle depends on the

combination of air pressure, duration of dispense cycle,
viscosity of material, temperature, and dispense tip size. 

SPECIFICATIONS:

Size ..................................8" x 5" x 5" (20.3 x 12.7 x 12.7 cm)
Weight..............................4.1 lbs. (1.86 kg)
Input Pressure .................60 PSI Min. (4.1 Bar) 

100 PSI Max. (7 Bar)

Operating Pressure..........20 - 100 PSI (1.4 - 7 Bar)
Suck-Back........................To 15" Hg, activated when foot pedal

is released.