Thank you for purchasing the AccuReader wafer 

reading system by LockTech.  This system will allow you 
to read the new GM locks commonly called  “Z-key.” 
Following a few simple steps it takes only minutes to 
read the depths for each cut in each position of a given 
lock. (ignitions excluded)

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock.  By 
checking the deepest cut first you eliminate what the 
cuts are not.  Therefore it is essential to always read 
depth slide #5 first.

Warded or Non Warded

The GM-Z AccuReader comes with two sets of 

slides, one is for Non Warded locks and one is for 
Warded locks.

To determine whether a lock is warded or 

non warded insert the AccuReader fully into the 
lock.    Either the “W” row of holes or the “NW” row 
of holes will only have 1 hole outside of the lock. 
The row of holes that only has 1 hole showing 
determines whether the lock is warded or non 
warded.

 

Once it has been determined which lock you are 

decoding, use the appropriate set of slides and proceed 
to the appropriate section of the instructions.  

ALWAYS start by thoroughly flushing the 

lock and run a key blank in and out several times to 
exercise the wafers.

Let me say that again,

ALWAYS start by thoroughly flushing the 

lock and run a key blank in and out several times to 
exercise the wafers.

SPACING

The GM-Z AccuReader has two sets of 10 holes 

drilled in to it.  One set is for warded locks and one set if 
for non warded locks.  
To determine the space currently being read,

Use the appropriate set of holes for the lock 
being read (W=warded)(NW=non warded).

Once the AccuReader has been inserted into 
the lock, count back from 10 the number of 
holes that are showing outside the lock. (see 
diagram)

NON WARDED LOCKS

Use the insertion tool to move the AccuReader 

key to the space to be read.

Use slight pressure pushing inward on the key 

to keep it flush up against the wafer being read.

Using the GM-Z #5 depth slide, fully insert it into 

the AccuReader key.  The alignment mark on the depth 
slide will line up with the (

Y

Yes

 mark 

or

 it will line up 

with the (

N

)

 No 

mark.

If the #5 depth slide lines up with the 

Y

 then the 

depth for that position is a 5.  If the depth slide lines up 
with a 

N

, then you must proceed to the #4 depth slide. 

((Only proceed to the #4 slide if the #5 slide read a 
No))

If the #4 depth slide lines up with the 

Y

 then the 

depth for that position is a 4.  If the depth slide lines up 
with a 

N

, then you must proceed to the #3 depth slide.

If the #3 depth slide lines up with the 

Y

 then the 

depth for that position is a  3.  If the depth slide lines up 
with a 

N

, then you must proceed to the #2 depth slide.

If the #2 depth slide lines up with the 

Y

 then the 

depth for that position is a 2.  If the depth slide lines up 
with a 

N

, then the depth for that position is a 1.

WARDED LOCKS

Use the insertion tool to move the AccuReader 

key to the space to be read.

Use slight pressure pushing inward on the key 

to keep it flush up against the wafer being read.

Using the GM-Z #5/4 depth slide, fully insert it 

into the AccuReader key.  The alignment mark on the 
depth slide will line up with the (

Y

Yes

 mark 

or

 it will 

line up with the (

N

)

 No 

mark.

If the GM-Z #5/4 depth slide lines up with the 

Отзывы: