Thank you for purchasing the AccuReader 

wafer reading system by LockTech.  This system will 
allow you to read the Ford 8 cut locks from Huf, Non 
Huf, and Non-Sidebar Ignitions.  Following a few 
simple steps it takes only minutes to read the depths 
for each cut in each position of a given lock.

 

 
 

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock.  
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #5 first. 
 
 

The Ford8 AccuReader comes with two sets 

of slides, one is for Non Huf locks and one is for Huf 
locks.  Once it has been determined which lock you 
are decoding, use the appropriate set of slides and 
proceed to the appropriate section of the instructions.   
 
 

Also supplied are two AccuReader keys, one 

is for reading spacing 8-5 and one is for reading 4-1. 

 
 

ALWAYS start by thoroughly flushing the 

lock and run a key blank in and out several times 
to exercise the wafers. 
 

 

Insert the 8-5 AccuReader key all the way 

into the lock using the insertion/release tool. Remove 
the insertion/release tool and pull outward on the key 
until it traps a wafer.  The number that is just outside 
the lock face will indicate which position you have 
trapped. 
 
 

Always start reading with the #5 depth slide 

tool, then proceed to #4, #3, & #2 in order,

 ((if 

necessary.))

 

 

Determine Huf or Non Huf 

 
 

NON HUF LOCKS 
 

 

Using the Ford8 #5 depth slide, fully insert it 

into the AccuReader key.  The alignment mark on the 
depth slide will line up with the (

Y

Yes

 mark 

or

 it will 

line up with the (

N

)

 No 

mark. 

 
 

If the #5 depth slide lines up with the 

Y

 then 

the depth for that position is a 5.  If the depth slide 
lines up with a 

N

, then you must proceed to the #4 

depth slide.

 

 
 

If the #4 depth slide lines up with the 

Y

 then 

the depth for that position is a 4.  If the depth slide 
lines up with a 

N

, then you must proceed to the #3 

depth slide.

 

 
 

If the #3 depth slide lines up with the 

Y

 then 

the depth for that position is a  3.  If the depth slide 
lines up with a 

N

, then you must proceed to the #2 

depth slide.

 

 
 

If the #2 depth slide lines up with the 

Y

 then 

the depth for that position is a 2.  If the depth slide 
lines up with a 

N

, then the depth for that position is a 

1.

 

 
 

Once you have read any positions in 8-5 

remove the key and fully insert the 4-1 AccuReader 
key and trap a wafer in the same manner as just 
described.  Once the lock is completely read, a fill 
program or progression can be used to make a 
complete key or read a different lock such as a trunk 
which may have a different wafer orientation and 
further narrow down the possibilities for making a 
complete key. 
 
 

HUF LOCKS 
 

 

Using the Ford8 HUF #5 depth slide, fully 

insert it into the AccuReader key.  The alignment 
mark on the depth slide will line up with the (

Y

Yes

 

mark 

or

 it will line up with the (

N

)

 No 

mark. 

 
 

If the #5 HUF depth slide lines up with the 

Y

 

then the depth for that position is a 5.  If the depth 
slide lines up with a 

N

, then you must proceed to the 

#4/3 depth slide.

 

 
 

If the #4/3 Huf depth slide lines up with the 

Y

 

then the depth for that position is a 4 or a 3(this is 
because in a Huf lock the #4 & #3 depth wafers rest 
at the same height in the lock).  All wafers that read 
Yes on the # 4/3 Huf slide should be cut at a 3 ½.  
Impression all 3 ½ positions, any marks should be cut 
to a 4 and all others cut to a 3.  If the depth slide lines 