Thank you for purchasing the AccuReader by 

LockTech wafer reading system.  This system will 
allow you to read the door/trunk locks for the Chrysler 
8 cut locks.  Following a few simple steps it takes 
only minutes to read the depths for each cut in each 
position and produce a finished key.

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock. 
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #4 first.

The AccuReader key is designed to read any 

wafers in positions 1-8.  Most Chrysler doors/trunks 
will have positions 2-8, once a working key is made 
for the door simply progress space 1 for a finished 
key.

ALWAYS start by thoroughly flushing the 

lock and run a key blank in and out several times 
to exercise the wafers.

Let me say that again,

ALWAYS start by thoroughly flushing the 

lock and run a key blank in and out several times 
to exercise the wafers.

SPACING

The spacing holes drilled into the key will 

identify which space is trapped on most makes & 
models.  Simply start with number 8 and count 
backwards the number of holes that are visible 
outside the lock.  For example, with the AccuReader 
key inserted, if 1 hole is visible then space 8 is 
trapped.  If 3 holes are visible then space 6 is 
trapped, and so-on...if 6 holes are visible the space 3 
is trapped.

Please take the time to familiarize yourself 

with the tools and verify all pieces are accounted for 
from the list of contents below:

Package Contents:
1-AccuReader key
1-insertion/release slide
1-depth slide #4
1-depth slide #3
1-depth slide #2
1-Tube storage container
1-Tube Cap

USING THE ACCUREADER

1) Always thoroughly clean the lock with a electronics 
safe cleaner to free any potentially stuck wafers.

2) Use the alignment holes through the AccuReader 
key to assist in judging the distance from one wafer 
position to the next.

3) Place the insertion/release slide in the slot on the 
AccuReader key.  Fully insert the AccuReader key 
into the keyway and remove the slide.  Pull outward 
lightly until a wafer traps.  You should either have 
space 7 or 8 trapped at this time.  To determine 
which space it is refer to the SPACING section. 

Once the desired wafer is trapped

4) Always

 start reading with the #4 depth slide 

tool, then proceed to #3 & #2 in order, IF 
NECESSARY! 

 Fully insert the #4 depth slide into the 

AccuReader key.  The alignment mark on the depth 
slide will line up with the (

Y

Yes

 mark or it will line up 

with the (

N

)

 No 

mark. 

 

a) If the #4 depth slide lines up with the 

then the depth for the trapped wafer is a 4.  If the 
depth slide lines up with a 

N

, then you must proceed 

to the #3 depth slide. 

((Only proceed to the #3 slide 

if the #4 slide read a No))

 

b) If the #3 depth slide lines up with the 

then the depth for the trapped wafer is a 3.  If the 
depth slide lines up with a 

N

, then you must 

proceed to the #2 depth slide.

c) If the #2 depth slide lines up with the 

then the depth for the trapped wafer is a 2.  If the 
depth slide lines up with a 

N

, then the depth is a 1.

d) Repeat steps 

a

 through 

c

 for each wafer 

position until you have recorded the depth for wafers 
in the lock.

e) Once you have all of the spaces in the 

door/trunk lock, normally 2-8 it is recommended to 
use a fill program or progress space #1 for a finished 
key.