6.3
Safety devices
Fig. Safety devices
1
4
2
3
1. Temperature sensor
2. Gas control valve
3. Air proving switch
4. Flame probe
Safety devices of the water heater:
Temperature
sensor (1)
The water heater controls the water temperature
using a temperature sensor:
-
T < 5 ºC, frost protection is activated.
-
T > 90 ºC, max. temperature.
-
T > 97 ºC, for extra safety.
Gas control valve (2)
The gas control valve controls the gas supply to
the burner.
Air proving switch (3)
The air proving switch guarantees the air supply
differential during pre-purging.
Flame probe (4)
The flame probe detects if there is a flame in the
burner.
Safety devices of the installation:
Expansion vessel
The expansion vessel stores temporarily expansion
water to keep the pressure in the installation at the
right level.
Expansion valve
The expansion valve prevents excessive pressure in
the tank of the water heater.
Pressure-reducing valve The pressure-reducing valve reduces the water
mains pressure, if necessary.
Temperature and
pressure relief valve
(T&P valve)
(1)
The T&P valve prevents excessive pressure and
temperature in the tank.
1 - All installations have a T&P valve connection. A T&P valve is mandatory for unvented installations.
Note
This manual only discusses unvented installations.
n
0312582_EcoSword_V4.0, 03-05-2021
31
Содержание EcoSword LGC 160-210 G P CE
Страница 11: ...User part 0312582_EcoSword_V4 0 03 05 2021 11 ...
Страница 12: ...12 ...
Страница 14: ...14 User part ...
Страница 16: ...16 User part ...
Страница 22: ...22 User part ...
Страница 25: ...Installation Maintenance and Service part 0312582_EcoSword_V4 0 03 05 2021 25 ...
Страница 26: ...26 User part ...
Страница 34: ...34 Installation Maintenance and Service part ...
Страница 56: ...56 Installation Maintenance and Service part ...
Страница 68: ...68 Installation Maintenance and Service part ...
Страница 85: ...13 4 Electrical wiring diagram 0312582_EcoSword_V4 0 03 05 2021 85 ...
Страница 90: ...90 Installation Maintenance and Service part ...
Страница 93: ......