Chapter 1: Alarms
HYDROBAR EXPRESS 220
1-25
Bar Stock Not Extracted from the Collet
BAR STOCK NOT
EXTRACTED FROM THE
COLLET!
POSSIBLE CAUSES:
-EXTRACTION DEVICE
MALFUNCTION
-SIGNAL SWITCH SQ5
DEFECTIVE OR
MIS-ADJUSTED
-MECHANICAL FAILURE
Description:
The Bar Stock Not Extracted From The Collet alarm occurs when input (I1.3 – SQ5) is not detected after the bar has been extracted
from the collet of the bar feed. Before the guiding channel opens to load a new bar, the remnant check device confirms that the
remnant has been extracted from the collet of the bar feed.
Solution:
•
Check that the extraction device jaws are not broken.
•
Check the adjustment of SQ5, the switch should only activate when no bar is present in the collet of the bar feed.
•
Contact LNS America Inc. for further information.
Содержание Hydrobar Express 220
Страница 61: ......
Страница 143: ......
Страница 147: ......
Страница 154: ...Chapter 6 Spare Parts Spare Parts 6 7 HYDROBAR EXPRESS 220 Chapter 6 6 7 HYDROBAR EXPRESS 220 Chain Drive Assembly L F ...
Страница 155: ...6 8 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 8 Chapter 6 HYDROBAR EXPRESS 220 Chain Drive Assembly R F ...
Страница 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Страница 157: ...6 10 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 10 Chapter 6 HYDROBAR EXPRESS 220 Remnant Vise ...
Страница 158: ...Chapter 6 Spare Parts Spare Parts 6 11 HYDROBAR EXPRESS 220 Chapter 6 6 11 HYDROBAR EXPRESS 220 Sensor Support Assembly ...
Страница 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Страница 162: ...Chapter 6 Spare Parts Spare Parts 6 15 HYDROBAR EXPRESS 220 Chapter 6 6 15 HYDROBAR EXPRESS 220 Coding Disc Assembly ...
Страница 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Страница 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...