Chapter 1: Common Issues
HYDROBAR EXPRESS 220
1-18
Guiding Channel Malfunction During Opening SQ4
GUIDING CHANNEL
MALFUNCTION DURING
OPENING!
POSSIBLE CAUSES:
-OPENING MECHANISM
MALFUNCTION
-SIGNAL SWITCH SQ4
DEFECTIVE OR
MIS-ADJUSTED
Description:
The Guiding Channel Malfunction During Opening alarm occurs if input (I1.2 – SQ4) does not turn off after the channel opens.
Solution:
Press the HELP key. Press F4 (Page Down icon) twice.
Case Input Remote
Pendant
Solution
1
Bit 2 = 1
MODULE 1
76543210
100
The switch may be sticking and needs to be replaced.
2
Bit 2 = 0
MODULE 1
76543210
0
Alarm needs to be cleared. Press the STOP key on the remote
control station to clear the message and reset the alarm.
For case 1, after the solution has been completed, press the STOP key on the remote control station to clear the message and reset
the alarm.
Содержание Hydrobar Express 220
Страница 61: ......
Страница 143: ......
Страница 147: ......
Страница 154: ...Chapter 6 Spare Parts Spare Parts 6 7 HYDROBAR EXPRESS 220 Chapter 6 6 7 HYDROBAR EXPRESS 220 Chain Drive Assembly L F ...
Страница 155: ...6 8 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 8 Chapter 6 HYDROBAR EXPRESS 220 Chain Drive Assembly R F ...
Страница 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Страница 157: ...6 10 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 10 Chapter 6 HYDROBAR EXPRESS 220 Remnant Vise ...
Страница 158: ...Chapter 6 Spare Parts Spare Parts 6 11 HYDROBAR EXPRESS 220 Chapter 6 6 11 HYDROBAR EXPRESS 220 Sensor Support Assembly ...
Страница 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Страница 162: ...Chapter 6 Spare Parts Spare Parts 6 15 HYDROBAR EXPRESS 220 Chapter 6 6 15 HYDROBAR EXPRESS 220 Coding Disc Assembly ...
Страница 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Страница 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...