LMI RFP Series Скачать руководство пользователя страница 1

Instruction

Instruction

Instruction

Instruction

Instruction

     

Manual

Manual

Manual

Manual

Manual

Remote Flowmeter - Pulser

RFP Series

For file reference, please record the following data:

Model No: 
Serial No: 
Installation Date: 
Installation Location: 

When ordering replacement parts for your LMI Controller or accessory, please include
the complete Model Number and Serial Number of your unit.

Replaces same of Rev D 9/96

1538.D 6/97

CONTENTS

Unpacking................................................................... 2
Location ...................................................................... 2-3
Programmable Divider & Pump Calculations........ 4
Dimensions & Weights.............................................. 7
Specifications ............................................................. 10
Parts List ..................................................................... 11

Содержание RFP Series

Страница 1: ...g data Model No Serial No Installation Date Installation Location When ordering replacement parts for your LMI Controller or accessory please include the complete Model Number and Serial Number of you...

Страница 2: ...rupted run of straight pipe with a length at least 10 times the nominal diameter of the Flowmeter both upstream and downstream is need to ensure accurate readings 4 If the pipe line downstream from th...

Страница 3: ...1 Installation of your LMI metering pump should be in accordance with instructions included with the pump 2 Plug the connector from the programmable divider into the receptacle located on the bottom...

Страница 4: ...nit The speed of the pump is controlled automatically based on the flow of the water through the flowmeter On the LMI A7 pump external mode is accomplished by turning the speed knob fully counter cloc...

Страница 5: ...tting on pump and strokes per minute in step 5 C Example C Square Root of Percent output desired from pump C 3 DETERMINE THE STROKE SETTING Model Pipe Flow GPM Flow LPM Primary Pulses Primary Pulse Si...

Страница 6: ...emove the clear window on the programmable divider by removing the two black thumb screws B Set thumbwheel numbers to divider number determined above Example Using the divider number determined in the...

Страница 7: ...25 L1 mm 288 378 438 in 5 35 5 79 6 34 8 6 8 440 9 370 12 560 H mm 136 147 161 218 214 240 319 in 1 61 1 75 1 81 3 27 3 87 4 62 6 h mm 41 44 46 83 99 117 152 in 1 1 25 2 6 5 7 5 9 18 D mm 165 190 228...

Страница 8: ...8 RFP 07 RFP 10 RFP 15 RFP 20...

Страница 9: ...9 RFP 30 RFP 40 RFP 60...

Страница 10: ...RE 32 to 120 O F 0 to 50O C MAXIMUM OPERATING PRESSURE 200 psi 13 8 Bar RFP 30 RFP 40 RFP 60 TYPE Magnetic Drive Turbine Meter BODY Bronze REGISTER Straight reading US Gallons center sweep hand protec...

Страница 11: ...s All Models All Models All Models 31271 Remote Programmable Divider Asm 1 1 1 1 1 1 1 31135 Housing 1 26740 Gasket Asm 1 31277 Connector Asm 1 31278 Cable Asm 1 30990 Divider Asm 1 26314 Switch 1 264...

Страница 12: ...12 1996 LMI Milton Roy All Rights Reserved Printed in USA Specifications subject to change without notice...