background image

Instruction 

Sheet

MP-100  Analog to Digital Converter

Input Signal Source: 

4-20 mA (isolated) only.

Max Input  Voltage: 

42VDC

Impedance: 

100 Ohms

INSTALLATION

1.

Disconnect signal source supply voltage prior to
connecting your MP-100. Failure to do so may damage
the MP-100 circuit.

2.

Insert the 4-pin connector into the socket on your LMI
Series A7, B7 or C7 Metering Pump. The socket is
located on the bottom right under the pump control
panel.

3.

Connect the other end of the cable to your input
signal source. Polarity is:
white = po); black = negative (-).

Replaces same of Rev. B  7/97

1631.C  7/99

Micropace™ Electronic Metering Control Modules

MP-100 Series Loop Control

Power Supply:

15 VDC, Supplied by
LMI pump

Ambient Temperature:

0

0

F to 140

0

F

(-20

0

C to 60

0

C)

Enclosure:

Splash & dust proof,
IP-65 rated

MICROPACE

®

LIQUID METRONICS DIVISION

Specifications and dimensions shown above are typical for all models.

MP-100 Typical Installation

LIQUID METRONICS DIVISION

MICROPACE

4 DIGIT MULTIPLIER

MODEL MP-500M

4

6

8

10

12

14

16

18

20

Span (range)
adjustment by
stroke length

Percent

Pump

Speed

milliAmp DC Signal

MP-100 Adjustment Range

8 Post Office Square

Acton, MA 01820 USA

TEL: (978) 263-9800

FAX: (978) 264-9172

http:\\www.lmipumps.com

(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com