Getting Started
How Gocator Legal for Trade Works
LMI’s Legal for Trade system requires sensor and component mounting, sensor
configuration, and alignment before measurements can be generated. While the
production system only requires the sensor and measurement display, a PC or laptop is
needed during sensor configuration. The process can be described as follows:
1. System installation. Mount sensor, encoder and Smart Display, assemble cordsets
and connect all devices to a suitable power supply.
2. Sensor configuration. Connect to the sensor using the Gocator Conveyor Utility and
adjust the active region to the width of your conveyor.
3. Zero and measurement display. Using the Smart Display, Zero the sensor to the
conveyor and start displaying package measurements.
Parts list
The items below are required to assemble the Gocator Legal for Trade system.
Item Number
Description
322490A-2-R-16-T
SENSOR, Gocator
2490A-2-R-16-T,
Legal for Trade, 660nm, Top
Mount
301251
ENCODER model
and open-ended
harness
301252
DISPLAY, model
from IDEC, Legal for Trade user
interface
301176-5m
Gocator CORDSET, 5m Power and Ethernet, 1x open wire end, 1x
RJ45 end
301175-5m
Gocator CORDSET, 5m I/O, open wire end
Gocator Legal for Trade User Manual