Ethernet Protocol • 147
Gocator 2000 Family
Start
The Start command starts the sensor system (system enters the Running state).
Command
Field
Type
Description
length
64s
Command size – in bytes.
id
64s
Command identifier (0x100D).
reserved
64s
Reserved field – set to 0.
Reply
Field
Type
Description
length
64s
Reply size – in bytes.
id
64s
Reply identifier.
status
64s
Reply status.
Scheduled Start
The scheduled start command starts the sensor system (system enters the Running state) at target time
or encoder value (depending on the trigger mode).
The time and encoder targets value should be set by adding a delay to the time and/or encoder tick
returned by Get Time and Get Encoder command. The delay should be set such that it covers the
command response time of the Scheduled start command.
Command
Field
Type
Description
length
64s
Command size – in bytes.
id
64s
Command identifier (0x101D).
time target
64s
Specify start time target, in microseconds.
encoder target
64s
Specify start encoder target in ticks.
Reply
Field
Type
Description
length
64s
Reply size – in bytes.
id
64s
Reply identifier (0x101D).
status
64s
Reply status.
Stop
The Stop command stops the sensor system (system enters the Ready state).
Command
Field
Type
Description
length
64s
Command size – in bytes.
id
64s
Command identifier (0x1001).
Reply
Field
Type
Description
length
64s
Reply size – in bytes.
id
64s
Reply identifier.
status
64s
Reply status.
Содержание Gocator 2000 Family
Страница 1: ...User s Manual Gocator 2000 Family Version 2 2 1 0 Revision A...
Страница 164: ...Specifications 164 Gocator 2000 Family Envelope 61 25 40 5 4 15 82 9 95 7...
Страница 166: ...Specifications 166 Gocator 2000 Family Envelope 33 90 80 2 9 84 3 99 7 10 6...
Страница 168: ...Specifications 168 Gocator 2000 Family Envelope 190 210 33 141 3 155 7 4 11...
Страница 170: ...Specifications 170 Gocator 2000 Family Envelope 33 300 400 214 9 229 2 10 3 3 2...
Страница 172: ...Specifications 172 Gocator 2000 Family Envelope 33 400 500 216 2 230 6 3 9 11...
Страница 174: ...Specifications 174 Gocator 2000 Family Envelope 33 350 800 A 3 7 10 8 215 8 230 3 DETAIL A SCALE 1 2...