Ethernet Protocol • 131
Gocator 2000 Family
Outputs
The Outputs element has the following sub-element types: Ethernet, Serial, Analog, and DigitalOutput.
Each of these subelements defines the output settings for a different type of Gocator output.
The
Source
identifiers that are used with
Video and profile
outputs are
profile source identifiers
. Refer to
the Profile Sources section (page 112) for more information.
The
Source
identifiers that are used with
Value
and
Decision
outputs correspond to the measurement
identifiers defined in the ProfileMeasurement element. E.g.
<ProfileMeasurement>
...
<Measurements>
<Width id=”1000”>
...
<Height id=”2000”>
...
<Outputs>
<Ethernet>
...
<Decision>1000,2000</Decision>
...
e
TherneT
The Ethernet element defines settings for Ethernet output.
Ethernet Child Elements
Element
Type
Description
Video
String
Setting for selected video sources (comma-delimited list).
Profile
String
Setting for selected profile sources (comma-delimited list).
RawProfile
String
Setting for selected raw profile sources (comma-delimited list)
Value
String
Setting for selected value sources (comma-delimited list).
Decision
String
Setting for selected decision sources (comma-delimited list).
VideoOptions
String
Constraint for eligible video sources (comma-delimited list).
ProfileOptions
String
Constraint for eligible profile sources (comma-delimited list).
RawProfileOptions
String
Constraint for eligible raw profile sources (comma-delimited list).
ValueOptions
String
Constraint for eligible value sources (comma-delimited list).
DecisionOptions
String
Constraint for eligible decision sources (comma-delimited list).
S
eriaL
The Serial element defines settings for Serial output.
Serial Child Elements
Element
Type
Description
Value
String
Setting for selected value sources (comma-delimited list).
Decision
String
Setting for selected decision sources (comma-delimited list).
ValueOptions
String
Constraint for eligible value sources (comma-delimited list).
DecisionOptions
String
Constraint for eligible decision sources (comma-delimited list).
a
naLog
The Analog element defines settings for Analog output.
The range of valid measurement values [DataScaleMin, DataScaleMax] is scaled linearly to the specified
current range [CurrentMin, CurrentMax].
Содержание Gocator 2000 Family
Страница 1: ...User s Manual Gocator 2000 Family Version 2 2 1 0 Revision A...
Страница 164: ...Specifications 164 Gocator 2000 Family Envelope 61 25 40 5 4 15 82 9 95 7...
Страница 166: ...Specifications 166 Gocator 2000 Family Envelope 33 90 80 2 9 84 3 99 7 10 6...
Страница 168: ...Specifications 168 Gocator 2000 Family Envelope 190 210 33 141 3 155 7 4 11...
Страница 170: ...Specifications 170 Gocator 2000 Family Envelope 33 300 400 214 9 229 2 10 3 3 2...
Страница 172: ...Specifications 172 Gocator 2000 Family Envelope 33 400 500 216 2 230 6 3 9 11...
Страница 174: ...Specifications 174 Gocator 2000 Family Envelope 33 350 800 A 3 7 10 8 215 8 230 3 DETAIL A SCALE 1 2...