19
3.2.5
Connection Guidelines
•
The maximum sensor load per station varies with station performance. Station CPU
usage should be monitored to ensure any core does not exceed 80% usage.
•
Sensors can be grouped into different sensor networks for multi-station systems.
Each station can only have a single network connection to the sensor network.
However, each station can have multiple network connections to the client network
which allows different client PCs to process data separately. This is accomplished
through the use of two NICs in the station, each on a different subnet with a different
static IP. Different channels can then be set up to direct data to separate client PCs.
3.3 FireSync Client (Basic)
FireSync Client is a software application that can be used to set up, demonstrate, or
diagnose problems with a scan 3x00 system. The following sections describe
how to use FireSync Client to connect to a system and verify that all connected devices
are functioning normally. For a detailed description of the FireSync Client application,
see the section entitled
FireSync Client (Complete)
in the
Software
chapter of this
manual.
3.3.1
Installation
The FireSync Client application is available for Windows, and can be downloaded from
the LMI Technologies support website. To begin, download the software and install it on
a suitable client machine. The client machine should have an Ethernet adaptor that can
be configured for a static IP address and that supports 1000 Mb/s operation.
The user provided Station PC is typically configured with the address 192.168.1.10, but
can be configured as required. Set the client machine to an available address on the
same subnet (e.g. 192.168.1.9) and then connect a suitable Ethernet cable from the
client machine to the Station.
If you are using multiple FireSync Stations, you may need to connect to each Station
individually in order to assign each Station unique IP addresses (both public and
private), using the
Set IP
command from the
Server
menu. After each Station has been
assigned a unique address, you can reconnect to all stations simultaneously.
Содержание chroma+scan 3155
Страница 1: ...chroma scan 3x00 Document Version 4 11 12 30...
Страница 14: ...14 3 1 1 Sensors chroma scan 3155 chroma scan 3250 chroma scan 3350...
Страница 31: ...31 5 5 Dimensions and Mounting 5 5 1 chroma scan 3155 Sensor Dimensions...
Страница 32: ...32 5 5 2 chroma scan 3250 Sensor Dimensions...
Страница 33: ...33 5 5 3 chroma scan 3350 Sensor Dimensions...
Страница 52: ...52 Recommended values 20 to 20 default is 0...