Sensors should be connected to earth ground
All sensors should be connected to earth ground through their housing. All sensors should be mounted
on an earth grounded frame using electrically conductive hardware to ensure the housing of the sensor
is connected to earth ground. Use a multi-meter to check the continuity between the sensor connector
and earth ground to ensure a proper connection.
Minimize voltage potential between system ground and sensor ground
Care should be taken to minimize the voltage potential between system ground (ground reference for
I/O signals) and sensor ground. This voltage potential can be determined by measuring the voltage
between Analog_out- and system ground. The maximum permissible voltage potential is 12 V but should
be kept below 10 V to avoid damage to the serial and encoder connections.
Gocator 2300 & 2880 I/O Connector
on page 409 for a description of connector pins used with
Gocator 2300 series sensors.
Use a suitable power supply
The +24 to +48 VDC power supply used with Gocator sensors should be an isolated supply with inrush
current protection or be able to handle a high capacitive load.
Use care when handling powered devices
Wires connecting to the sensor should not be handled while the sensor is powered. Doing so may cause
electrical shock to the user or damage to the equipment.
Environment and Lighting
Avoid strong ambient light sources
The imager used in this product is highly sensitive to ambient light hence stray light may have adverse
effects on measurement. Do not operate this device near windows or lighting fixtures that could
influence measurement. If the unit must be installed in an environment with high ambient light levels, a
lighting shield or similar device may need to be installed to prevent light from affecting measurement.
Avoid installing sensors in hazardous environments
To ensure reliable operation and to prevent damage to Gocator sensors, avoid installing the sensor in
locations
l
that are humid, dusty, or poorly ventilated;
l
with a high temperature, such as places exposed to direct sunlight;
l
where there are flammable or corrosive gases;
l
where the unit may be directly subjected to harsh vibration or impact;
l
where water, oil, or chemicals may splash onto the unit;
l
where static electricity is easily generated.
Ensure that ambient conditions are within specifications
Gocator sensors are suitable for operation between 0–50° C and 25–85% relative humidity (non-
condensing). Measurement error due to temperature is limited to 0.015% of full scale per degree C.
The Master 400/800/1200/2400 is similarly rated for operation between 0–50° C.
Содержание Gocator 2300 Series
Страница 1: ...USER MANUAL Gocator 2300 2880 Series Firmware version 4 3 x xx Document revision D ...
Страница 20: ...Gocator 2300 2880 Series Getting Started System Overview 20 ...
Страница 174: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 174 2D View 3D View Measurement Panel ...
Страница 184: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 184 Measurement Panel ...
Страница 189: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 189 ...
Страница 199: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 199 Measurement Panel ...
Страница 208: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 208 else Output_Set Volume 0 ...
Страница 387: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 387 Gocator 2320 Field of View Measurement Range Dimensions ...
Страница 388: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 388 Envelope Gocator 2330 Field of View Measurement Range ...
Страница 389: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 389 Dimensions Envelope ...
Страница 390: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 390 Gocator 2340 Field of View Measurement Range Dimensions ...
Страница 391: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 391 Envelope Gocator 2342 Field of View Measurement Range ...
Страница 392: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 392 Dimensions Envelope ...
Страница 393: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 393 Gocator 2350 Field of View Measurement Range Dimensions ...
Страница 394: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 394 Envelope ...
Страница 395: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 395 Gocator 2370 Field of View Measurement Range ...
Страница 396: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 396 Dimensions ...
Страница 397: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 397 Envelope ...
Страница 398: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 398 Gocator 2375 Field of View Measurement Range Dimensions ...
Страница 399: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 399 Envelope ...
Страница 400: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 400 Gocator 2380 Field of View Measurement Range ...
Страница 401: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 401 Dimensions ...
Страница 402: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 402 Envelope ...
Страница 405: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 405 Dimensions ...
Страница 406: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 406 Envelope ...