Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 71
Creating, Saving and Loading Jobs (Settings)
A Gocator can store several hundred jobs. Being able to switch between jobs is useful when a Gocator is
used with different constraints during separate production runs. For example, width decision minimum
and maximum values might allow greater variation during one production run of a part, but might allow
less variation during another production run, depending on the desired grade of the part.
Most of the settings that can be changed in the Gocator's web interface, such as the ones in the
Manage
,
Measure
, and
Output
pages, are temporary until saved in a job file. Each sensor can have
multiple job files. If there is a job file that is designated as the default, it will be loaded automatically
when the sensor is reset.
When you change sensor settings using the Gocator web interface in the emulator, some changes are
saved automatically, while other changes are temporary until you save them manually. The following
table lists the types of information that can be saved in a sensor.
Setting Type
Behavior
Job
Most of the settings that can be changed in the Gocator's web interface, such as the ones
in the
Manage
,
Measure
, and
Output
pages, are temporary until saved in a job file.
Each sensor can have multiple job files. If there is a job file that is designated as the
default, it will be loaded automatically when the sensor is reset.
Alignment
Alignment can either be fixed or dynamic, as controlled by the
Alignment Reference
setting in
Motion and Alignment
in the
Manage
page.
Alignment is saved automatically at the end of the alignment procedure when
Alignment Reference
is set to
Fixed
. When
Alignment Reference
is set to
Dynamic
, however, you must manually save the job to save alignment.
Network Address
Network address changes are saved when you click the
Save
button in
Networking
on
the
Manage
page. The sensor must be reset before changes take effect.
The job drop-down list in the toolbar shows the jobs stored in the sensor. The job that is currently active
is listed at the top. The job name will be marked with "[unsaved]" to indicate any unsaved changes.
To create a job:
1.
Choose
[New]
in the job drop-down list and type a name for the job.
2.
Click the
Save
button
or press
Enter
to save the job.
The job is saved to sensor storage using the name you provided. Saving a job automatically sets it as
the default, that is, the job loaded when then sensor is restarted.
To save a job:
l
Click the
Save
button
.
Содержание Gocator 2130
Страница 250: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 250...
Страница 262: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 262 2D View 3D View...
Страница 263: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 263 Measurement Panel...
Страница 279: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 279 Measurement Panel...
Страница 285: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 285...
Страница 292: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 292 Measurement Panel...
Страница 298: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 298 2D View 3D View...
Страница 305: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 305 2D View 3D View...
Страница 309: ...Gocator Line Profile Sensors User Manual Gocator Web Interface 309 2D View 3D View...
Страница 586: ...Gocator Line Profile Sensors User Manual Specifications 587 Dimensions Envelope...
Страница 588: ...Gocator Line Profile Sensors User Manual Specifications 589 Envelope...
Страница 590: ...Gocator Line Profile Sensors User Manual Specifications 591 Dimensions Envelope...
Страница 592: ...Gocator Line Profile Sensors User Manual Specifications 593 Dimensions Envelope...
Страница 594: ...Gocator Line Profile Sensors User Manual Specifications 595 Dimensions...
Страница 595: ...Gocator Line Profile Sensors User Manual Specifications 596 Envelope...
Страница 597: ...Gocator Line Profile Sensors User Manual Specifications 598 Dimensions...
Страница 598: ...Gocator Line Profile Sensors User Manual Specifications 599 Envelope...
Страница 600: ...Gocator Line Profile Sensors User Manual Specifications 601 Dimensions...
Страница 601: ...Gocator Line Profile Sensors User Manual Specifications 602 Envelope...
Страница 603: ...Gocator Line Profile Sensors User Manual Specifications 604 Dimensions...
Страница 604: ...Gocator Line Profile Sensors User Manual Specifications 605 Envelope...
Страница 608: ...Gocator Line Profile Sensors User Manual Specifications 609 Dimensions...
Страница 609: ...Gocator Line Profile Sensors User Manual Specifications 610 Envelope...
Страница 611: ...Gocator Line Profile Sensors User Manual Specifications 612 Dimensions...
Страница 612: ...Gocator Line Profile Sensors User Manual Specifications 613 Envelope...
Страница 615: ...Gocator Line Profile Sensors User Manual Specifications 616 Dimensions...
Страница 616: ...Gocator Line Profile Sensors User Manual Specifications 617 Envelope...