Gocator Line Profile Sensors - User Manual
Protocols • Gocator Protocol • 381
GDP messages are always sent in groups. The Last Message flag in the
control
field is used to indicate the
final message in a group. If there is only one message per group, this bit will be set in each message.
Stamp
Field
Type
Offset
Description
size
32u
0
Count of bytes in message (including this field).
control
16u
4
Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 1.
count (C)
32u
6
Count of stamps in this message.
size
16u
10
Stamp size, in bytes (min: 56, current: 56).
source
8u
12
Source (0 – Main, 1 – Buddy).
reserved
8u
13
Reserved.
stamps[C]
Stamp
14
Array of stamps (see below).
Field
Type
Offset
Description
frameIndex
64u
0
Frame index (counts up from zero).
timestamp
64u
8
Timestamp (µs).
encoder
64s
16
Current encoder value (ticks).
encoderAtZ
64s
24
Encoder value latched at z/index mark (ticks).
status
64u
32
Bit field containing various frame information:
Bit 0: sensor digital input state
Bit 4: master digital input state
Bit 8-9: inter-frame digital pulse trigger (Master digital input if
master is connected, otherwise sensor digital input. Value is
cleared after each frame and clamped at 3 if more than 3 pulses
are received).
serialNumber
32u
40
Sensor serial number. (In a dual-sensor system, the serial number
of the main sensor.)
reserved[2]
32u
44
Reserved.
Stamp
Video
Field
Type
Offset
Description
size
32u
0
Count of bytes in message (including this field).
control
16u
4
Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 2.
attributesSize
16u
6
Size of attributes, in bytes (min: 20, current: 20).
height (H)
32u
8
Image height, in pixels.
Содержание Gocator 2100 Series
Страница 10: ...Gocator Line Profile Sensors User Manual 10 Return Policy 515 Software Licenses 516 Support 522 Contact 523 ...
Страница 193: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 193 2D View 3D View Measurement Panel ...
Страница 197: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 197 ...
Страница 209: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 209 2D View 3D View ...
Страница 214: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 214 2D View 3D View ...
Страница 215: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 215 ...
Страница 225: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 225 2D View 3D View ...
Страница 462: ...Gocator Line Profile Sensors User Manual Specifications Sensors 462 Dimensions Envelope ...
Страница 464: ...Gocator Line Profile Sensors User Manual Specifications Sensors 464 Envelope ...
Страница 466: ...Gocator Line Profile Sensors User Manual Specifications Sensors 466 Dimensions Envelope ...
Страница 468: ...Gocator Line Profile Sensors User Manual Specifications Sensors 468 Dimensions Envelope ...
Страница 470: ...Gocator Line Profile Sensors User Manual Specifications Sensors 470 Dimensions ...
Страница 471: ...Gocator Line Profile Sensors User Manual Specifications Sensors 471 Envelope ...
Страница 473: ...Gocator Line Profile Sensors User Manual Specifications Sensors 473 Dimensions ...
Страница 474: ...Gocator Line Profile Sensors User Manual Specifications Sensors 474 Envelope ...
Страница 476: ...Gocator Line Profile Sensors User Manual Specifications Sensors 476 Dimensions ...
Страница 477: ...Gocator Line Profile Sensors User Manual Specifications Sensors 477 Envelope ...
Страница 479: ...Gocator Line Profile Sensors User Manual Specifications Sensors 479 Dimensions ...
Страница 480: ...Gocator Line Profile Sensors User Manual Specifications Sensors 480 Envelope ...
Страница 484: ...Gocator Line Profile Sensors User Manual Specifications Sensors 484 Dimensions ...
Страница 485: ...Gocator Line Profile Sensors User Manual Specifications Sensors 485 Envelope ...
Страница 487: ...Gocator Line Profile Sensors User Manual Specifications Sensors 487 Dimensions ...
Страница 488: ...Gocator Line Profile Sensors User Manual Specifications Sensors 488 Envelope ...
Страница 491: ...Gocator Line Profile Sensors User Manual Specifications Sensors 491 Dimensions ...
Страница 492: ...Gocator Line Profile Sensors User Manual Specifications Sensors 492 Envelope ...
Страница 506: ...Gocator Line Profile Sensors User Manual Specifications Master Hubs 506 Master 810 Dimensions ...
Страница 512: ...Gocator Line Profile Sensors User Manual Specifications Master Hubs 512 Master 2410 Dimensions ...