Содержание Intercom unit 7.2

Страница 1: ...Lift Complex DS OOO Intercom unit 7 2 OPERATIONS MANUAL LNGS 465213 270 500 OM Edition 7 Novosibirsk 2018...

Страница 2: ...ions 7 2 SETTING UP 7 2 1 Setting up the device 7 2 2 Making internal network 8 2 3 Connecting internal battery 9 2 4 Wiring IU 7 2 10 3 MAINTENANCE 10 3 1 General instructions 10 3 2 Quarterly mainte...

Страница 3: ...les usage transportation storage and maintenance The manual covers Intercom units 7 2 of the following options LNGS 465213 270 500 LNGS 465213 270 500 01 LNGS 465213 270 500 02 When using Intercom Uni...

Страница 4: ...6 Overall dimension no more including holder 104 68 24mm 1 3 7 Weight no more 0 2Kg 1 3 8 Max quantity of devices in CAN bus 2pcs 1 3 9 Max distance to Landing Intercom and indicator should not excee...

Страница 5: ...GND CALL SPC 4 2 1 3 CALL button Mode setting CABIN PIT TRM jumper MODE Wi Fi CAN Fig 1 Appearance of IU 7 2 sockets controls and indicators Table 1 Meaning of indicators Name Status Colour Meaning MO...

Страница 6: ...nternal battery wiring XP3 CAN bus to connect additional devices jumpers to select mode PIT CABIN and TRM termination Socket details are as shown in Table 2 Table 2 Socket details Socket Pin Label Des...

Страница 7: ...PIT button on the LU When connection established backhighlighted CALL button lits and indicator PIT on LU starts flashing To change the direction press CALL button on IU 7 2 or press PIT button on LU...

Страница 8: ...nstalled to IU to power the device from battery wait more than 10 sec blinking of LEDs MODE WI FI CAN with red green colour then release the CALL button 2 1 3 Installing and connecting IU Connection I...

Страница 9: ...13 270 500 02 Edition 07 Lift Monitoring and Diagnostics System 27 08 19 p 9 3 2 1 4 4 3 2 1 Fig 3 Internal network architecture 2 3 Connecting internal battery IU 7 2 has built in accumulator battery...

Страница 10: ...instructions 3 1 1 Maintenance is carried out according to a preventive system which provides quarterly maintenance 3 1 2 The battery installed in IU 7 2 has a limited service life 2 3 years After the...

Страница 11: ...rting installation 5 2 Safety regulations When carrying out installation the following rules should be taken into account National legislation rules mandatory regulatory and technical documentation re...

Страница 12: ...erate cold climatic region 7 3 Storage rooms must be free from dust vapor of acids or alkali aggressive gases and other harmful or corrosive substances 8 TRANSPORTATION 8 1 Packed Intercom Unit 7 2 mu...

Страница 13: ...s manual LNGS 465213 270 500 OM LNGS 465213 270 500 LNGS 465213 270 500 01 LNGS 465213 270 500 02 Edition 07 Lift Monitoring and Diagnostics System 27 08 19 p 13 Appendix 1 Intercom Unit 7 2 Overall a...

Страница 14: ...al LNGS 465213 270 500 OM LNGS 465213 270 500 LNGS 465213 270 500 01 LNGS 465213 270 500 02 Edition 07 Lift Monitoring and Diagnostics System 27 08 19 p 14 Appendix 2 Intercom Unit 7 2 Wiring diagram...

Страница 15: ...Diagnostics System 27 08 19 p 15 Appendix 3 Input control Output control Dry contact in SW Inputs Buttons of IU 7 2 Output in SW Output of IU 7 2 00 CALL button 00 GLED 01 Default button 01 YLED 02 I...

Страница 16: ...RS 3 98 Background music Background music playback 9 8 _ MUSIC The priority of an event is determined by its number The smaller the number the higher the priority The table shows the events supported...

Страница 17: ..._ datetime 12 31 2015 24 00 00 the beginning of the permission to form an event to_datetime 12 31 2099 00 00 01 end of event resolution counter 0 xffff limiting the number of generated messages 0 xFF...

Страница 18: ...1 total left channel gain in the period from 0 00 to 2 59 KDiv _ L 32 KMul _ R 1 the total gain of the right channel in the period from 0 00 to 2 59 KDiv_R 32 5 EVENT FILE NAMES 5 1 Event Dispatcher...

Страница 19: ...018 wav Seventeenth floor 18 019 wav Eighteenth floor 19 020 wav Nineteenth floor 20 021 wav Twentieth floor 21 022 wav Twenty first floor 22 023 wav Twenty second floor 23 024 wav Twenty third floor...

Страница 20: ...xth floor 57 058 wav Fifty seventh floor 58 059 wav Fifty eighth floor 59 060 wav Fifty ninth floor 60 061 wav 60th floor 61 062 wav Sixty ground floor 62 063 wav Sixty second floor 63 064 wav Sixty t...

Страница 21: ...v Exit zone 110 wav Hall 111 wav Reception desk 112 wav Arrival 113 wav Departure 114 wav Mezzanine 129 wav Open terrace 130 wav Platform 131 wav Gallery 132 wav Atrium 133 wav Pavilion 134 wav Recept...

Страница 22: ...um number of files in the folder is not strictly stipulated the recommended value is 8 10 files SD _ RIN consistently loses all the files from the folder and then goes to the next folder If there are...

Страница 23: ...ations manual LNGS 465213 270 500 OM LNGS 465213 270 500 LNGS 465213 270 500 01 LNGS 465213 270 500 02 Edition 07 Lift Monitoring and Diagnostics System 27 08 19 p 23 21 SWE Swedish 22 TUR Turkish 23...

Отзывы: