Design

LK  Webserver  is  used  to  access  and  control  

LK  Room  Temperature  Control  ICS.2  and/or 

LK Water Safety System WSS via the Internet or 

a local network. The interface is suitable for cell 

phones, tablets or computers and can be reached 

via a website or an app for Android and Apple 

IOS. Interface updates continually take place and 

new  functions  will  be  available,  see  the  latest 

manual at www.lksystems.se/en.

LK  Webserver  continually  logs  the 

fl

oor  heating  

system  (temperatures,  heat  to/from  etc.)  to  

enable  optimization  of  the  performance  of  the 

fl

oor  heating  systems.  The  logged  data  can  be 

retrieved and analyzed with LK Analyzer ICS.2 

software  which  can  be  downloaded  from  the  

LK Systems website.

Installation of the LK Webserver

The  webserver  can  only  be  connected  to  the  

LK Receiver 8 ICS.2 and LK Water Safety System 

WSS. The webserver is placed  near a room tem-

perature control if it is to be used for both 

fl

oor 

heating and water safety system. Otherwise it can 

be located near a network socket and then com-

municate  wirelessly with the master unit of  the 

water safety system. 

The webserver can be installed in three differ-
ent ways:

1   Only for an LK Receiver 8 ICS.2, start the 

installation at point 1 in the instructions below. 

 

2   Using two webservers to create a wireless 

bridge when an internet connection is not avail-

able near the receiver of the 

fl

oor heating instal-

lation. Begin installation as shown below in 

point 1 in the instructions.
3   Only for the LK Water Safety System WSS, 

begin installation as shown below in point 11 in 
the instructions.

1

  

  

Connecting the LK Receiver 8 ICS.2 with  

      LK Webserver

An example of a system with the webserver connected by cable 
to the router. The webserver is connected to both the water safety 
system and room temperature control ICS.2. 

1.  Attach the webserver with a suitable screw.
2.  Switch off the power to the LK Receiver.
3.  Connection is done with a three-conductor 

cable (> 0.25 mm

2

). Connect the LK Receiver 

8 ICS.2 (Master) three-pole busbar marked-

BUS

 with cable to the three-pole connection 

of the LK Webserver marked BUS ICS.2. 

Connect pole to pole, i.e. plus [+] is connect-

ed to plus [+], minus [-] to minus [-] and zero 

[0] to zero [0].  

 

 

BUS cable 

4.  Energize the LK Receiver.
5.  Connect the cable from the mains adapter to 

the input Power 5 V DC input on the web-

server, connect the mains adapter to a wall 

socket. 

6.  Connect the network cable between the 

webserver’s ethernet

-

connection and a 

network socket with internet access. 

 

 

EN.33.C.190.1709

Содержание LK Webserver

Страница 1: ...alled in three differ ent ways 1 Only for an LK Receiver 8 ICS 2 start the installation at point 1 in the instructions below 2 Using two webservers to create a wireless bridge when an internet connection is not avail able near the receiver of the floor heating instal lation Begin installation as shown below in point 1 in the instructions 3 Only for the LK Water Safety System WSS begin installation...

Страница 2: ... user interface channel 6 is normally used 3 Connecting LK Master Unit WSS with LK Webserver 11 The LK Master unit WSS communicates wirelessly with the webserver connected to the network socket with internet access 12 Connect the cable from the mains adapter to the input Power 5 V DC input on the web server connect the mains adapter to a wall socket 13 Connect the network cable between the webserv...

Страница 3: ... also an app for the webserver that can be downloaded from Google play and the Apple Appstore The app is called LK AtHome 8 Reset the password on the login page Login Reset password The password can be reset with the Reset password function An email with instruc tions is sent to the registered email address 9 If the webserver does not have internet ac cess connect a computer using Windows to your ...

Страница 4: ...vers and connected room ther mostats 2 4 5 10 9 8 7 6 3 3 1 Basic functions 1 Menu tabs 2 Update button The webpage is automatically updated as soon as a change is made to the webpage or every tenth minute 3 Device name preselected as Receiver 1 i e Receiver 1 Click on the name Receiver 1 and rename the unit to a chosen name for exam ple after its location or the part of the system that it serves ...

Страница 5: ...nformation see the accompa nying manual LK Room Temperature Control ICS 2 Menu tab System Under the tab System overall system func tions can be set i e functions that affect all room thermostats in the facility An example of a function is Holiday vacation function If this is activated all thermostats of the facil ity will lower the set room temperature There is a clickable icon information icon fo...

Страница 6: ...essure for cold and warm water Status for external input Adjust the temperature alarm value between 0 and 15 C default 5 C Value for the pressure alarm Software version Address of the unit Values for DIP switches Menu tab Water Master Unit expanded Control panel Input link are shown as Control panel When clicking on the gear for Control panel the information below is shown Power supply battery sta...

Страница 7: ...hermotab and Watertab as well as all log data will also be erased The wireless connection to the master unit of the Water Safety System will be terminated The webserver is reset as follows Remove the charger to the unit Hold the red Reset Mating button down Reconnect the charger and continue to hold down the red button After 10 sec release the red button Versions From version 3 1 850 in the perman...

Отзывы: