background image

1

LK Wireless Room Control Cq (NC).

LK Actuator 24V AC

Connect the actuators, bearing in mind the fol-

lowing:

A control zone consists of 1 LK Room Thermostat 

(transmitter) but can contain one or more under 

floor heating loops equipped with actuators. All 

actuators in a control zone must be connected to 

a common channel on the receiver unit.

To aid assembly to the manifold, the actuators are 

supplied “open”. Once an actuator is powered 

(for a minimum of 6 minutes) an internal pin is 

released and the actuator will now operate.

LK Actuator.

Design

The LK Room Thermostat Cq (transmitter) regula-

tes the temperature in a zone (e.g. a room) via ra-

dio signals to the receiver unit. NOTE: Locate the 

receiver unit close to the heating circuit manifold.

The receiver unit converts radio signals to control 

signals to activate the actuators.

The receiver unit is available in three sizes:

• 

LK Cq 1 intended for 1 control zone.

• 

LK Cq 4 for a maximum of 4 control zones, 

(channel 1 - 4).

• 

LK Cq 6 for a maximum of 6 control zones, 

(channel 1 - 6).

The receiver unit functions along the same prin-

ciples, but the Cq 1 unit, which only has one re-

ceiver channel, differs somewhat in its design. 

The instructions for this model therefore contain 

a few additions.

Requirements

A suitably qualified electrician or installation 

engineer, must carry out electrical installation in 

accordance with the circuit diagram figs. 1 + 2. To 

achieve protection class 2, all necessary installa-

tion measures must be taken.

Installation and start-up (memorizing) is best car-

ried out in the following order:

The receiver unit

The receiver unit should be located close to hea-

ting circuit manifold to avoid lengthening the ac-

tuator connection cables.

In certain circumstances, the transmitters (ther-

mostat) signal may be too weak, e.g. if the recei-

ver unit is assembled in a metal enclosure (e.g. 

LK Manifold Cabinet). In these cases, the LK Re-

peater Cq should be used. See separate section, 

LK Repeater Cq.

LK Wireless Room Control Cq 1, 4 & 6 (NC)

EN.33.C.29.

Assembly instructions | LK Wireless Room Control Cq 1, 4 & 6 (NC)

Содержание Cq 1

Страница 1: ...ximum of 4 control zones channel 1 4 LK Cq 6 for a maximum of 6 control zones channel 1 6 The receiver unit functions along the same prin ciples but the Cq 1 unit which only has one re ceiver channel...

Страница 2: ...e ac tuators Cq 4 and Cq 6 receiver units can operate a maximum of 16 actuators When connecting two or more actuators to the same channel the connections must be only to the double circuit boards a ch...

Страница 3: ...the indicator light will come on Activating the room thermostat Press and hold the lower black button B Briefly press the upper black button C When the indicator light D is lit release the lower butto...

Страница 4: ...ment dial the indicator light on the receiver s channel will be lit or switched off respectively within approx imately 30 seconds Dial towards maximum temperature the light on the receiver unit comes...

Страница 5: ...normal once power is restored Pump control for Cq 4 and Cq 6 The last channels on the receiver Cq 4 channel 4 and Cq 6 channel 6 can start or stop a circula ting pump However Cq 4 becomes 3 channel a...

Страница 6: ...minutes the output will return to its correct position Any radio con nection established will not be affected Valve exercising The actuator disconnects once a day for 3 mi nutes and opens the valve o...

Страница 7: ...tes total on and off time Measurement interval Approximately 10 minutes Type Heat Cool Valve exercising Once a day for 3 minutes can be switched off BR1 Temperature sensor NTC Transfer frequency 868 M...

Отзывы: