Electrical Connection
6.1
Wiring Diagram
Wiring Diagram for
European
In Australia and New Zealand, electrical installation and maintenance
shall be conducted by a licensed electrician and shall comply with
Australia/New Zealand National Wiring Rules.
Because the inverter does not maintain neutral integrity, an external
neutral connection must be used in Australia and New Zealand. 30mA
Type “A” RCD can be used where required by AS/NZ
3000, but cannot
be used if there are backup loads on the inverter as per AS4777.
PV1+
PV1-
PV2+
PV2-
RCD
PE N L
Smart
Meter
E-Bar
Hybrid Inverter
Battery
BATTERY
PV
1
PV
2
BMS
MULTI
EPS
GR
ID
EPS
Load
General
Load
Transfer
Switch
kWh
Energy
Meter
RCD