Programmable thermostat user manual
Keys
Stand-by
Function keys
3.2 Stand-by
In stand-by mode, the heating function is disabled and the display shows only the current
time.
The display flashes if the clock is not set and synchronised; see clock setting.
To switch from stand-by to operating mode, press and hold the stand-by key for two seconds
until the display shows "ON".
3.3 Programmable thermostat mode
The Livingstone radiant panel features a programmable thermostat that can be programmed
24x7 on thermostat mode when the display shows the function (see figure) and the daily
schedule on the side.
To change the programming, refer to chapter “Weekly programming 24x7”.
In this mode, the thermostat follows the daily schedule, alternating comfort and night
setback modes.
The programmable thermostat function is disabled if the clock is not set, for example, after
prolonged blackouts (display will flash); in this case, the heater will remain at comfort
temperature until the clock is set to the current time.
3.4 Pilot wire mode (Fil pilote)
In Pilot wire mode, the thermostat is controlled remotely via a wire protocol, TERMO-DL,
which support 6 commands.
Pilot wire commands:
1)
Comfort: Comfort temperature
2)
Night setback mode: Comfort temperature -3.5 ° C
3)
ECO1: Comfort temperature -1 ° C
4)
ECO2: Comfort temperature -2 ° C
5)
Anti-freeze: Minimum anti-freeze temperature 7 °C
6)
Stop: Heating disabled
3.5 Comfort Mode
In comfort mode, temperature is regulated via the temperature knob.
8