Содержание L10.0E-02

Страница 1: ...1 L10 0E 02 Service Manual ...

Страница 2: ...ring Mode Overview 5 CHAPTER 3 ELECTRONIC DIAGRAMS 3 1 Electronic Diagram 6 CHAPTER 4 TROUBLE SHOOTING 4 1 Troubleshooting No RPM Displayed 7 4 2 Troubleshooting No Resistance or Incorrect Resistance 8 4 3 Troubleshooting No Power to the Console 10 4 4 Troubleshooting No or High Heart Rate 11 4 5 Troubleshooting Knocking or Creaking Noises 12 ...

Страница 3: ...3 CHAPTER 1 SERIAL NUMBER LOCATION 1 1 Serial Number Location ...

Страница 4: ...conds until Engineering Menu appears on the display 2 Use the LEVEL UP and DOWN keys to scroll through a list of parameters 3 Press CHANGE DISPLAY ENTER to enter a parameter setting 4 Use the INCLINE UP and DOWN keys to change the parameter and ENTER to save 5 Press and hold the STOP key to exit Engineering Mode and return to normal operation ...

Страница 5: ... Eng 2 Switch Function Press ENTER to scroll through the options in this menu and LEVEL UP or DOWN to test or change the settings components below Speed Mode Miles or Kilometers EUP On Off EUP Energy Using Products Directive Machine Set Set the region of the customer US or ID international Hold Stop 3 sec back to Engineering Menu Eng 3 Information Accumulated Hours and Distance Hold LEVEL UP and D...

Страница 6: ...6 CHAPTER 3 ELECTRONIC DIAGRAM ...

Страница 7: ...sent on the drive pulley 4 The console is defective Solution 1 Check the connection of the console cable at the console make sure there are no kinks or pinches of the console cable Replace the cable if any damage is found 2 Check the connection of the speed sensor wire at the ECB motor Also check the gap between the speed sensor and the magnet on pulley It should be within 5mm Adjust the gap if it...

Страница 8: ... and check the ECB motor At resistance level 1 the head of the steel rope should point towards the top right side around 45 degrees If the head of the steel rope points toward the bottom or left side the resistance will be reversed adjust the head of the steel rope to the correct position 3 Press the LEVEL UP key to adjust the resistance a If the ECB motor does not move the resistance will not be ...

Страница 9: ... too heavy check the gap between the orange block and the bottom of the ECB track It should be within 1 2 mm of the bottom of the ECB track If the gap is bigger than 1 2 mm the resistance will be heavier than normal Adjust the cable to the correct gap range 4 If all above conditions are ok and the resistance is still too heavy the magnet inside the ECB is defective Replace the ECB ...

Страница 10: ...1A Check to make sure the power adaptor on the unit is correct Test the power adaptor on a known good outlet Replace the adaptor if it is defective 2 Check the connection of the console cable at the console Unplug the console cable from console and use a multi meter to check the voltage through the console cable Normally it should be 12VDC If no voltage is present the console cable is defective re...

Страница 11: ...grip plates The HR grip should give a voltage reading of between 0 5 and 2 0VDC a If the voltage is not between 0 5 and 2 0VDC remove the 3 screws holding the HR grip together and check the connection of the HR grip wiring 2 Check continuity of the HR grip wiring a Place one terminal of a multi meter set for resistance on the HR grip wiring at the HR grip and the other terminal on the HR grip wiri...

Страница 12: ...al attention to areas where arms meet Tighten hardware where needed 2 If the noise is present only during incline check to make sure the Teflon washers are installed at the incline motor connection point Figure A a Lubricate the gear shaft of the incline motor with grease Vision recommends Super Lube brand Lithium Grease where available 3 Remove the covers and check the belt tension a Tighten the ...