OPERATION TESTING

Electrical Connections

5

Electrical Connections

Connect the power cord to a constant source of 115 volts.

• The pump should be connected or wired to its own circuit, with no other electric receptacles or 

equipment in the circuit. 

NOTE: 

Do not connect to a fan or any device that runs intermittently.

• The fuses or circuit breaker should be of ample capacity.

IMPORTANT:

 If the power cord is damaged, the whole unit must be replaced.

OPERATION TESTING

 

NOTE:

 If the unit is going to be idle for a period of time, refer to 

“Cleaning Impeller and Volute” on 

page 6

.

1. Connect a discharge hose to the pump's discharge port.
2. Place pump into the basin or a test reservoir.
3. Direct the opposite end of the discharge hose back into the basin or test reservoir so the water dis

-

charged will be contained within the basin or test reservoir.

4. Secure the hose to prevent it from exiting the basin or test reservoir due to high water pressure.
5. If there is a valve on the discharge hose, be sure it is open.
6. Fill the basin or test reservoir until the pump is fully submerged. 
7. Plug in the power cord.
8. Make sure a stream of water is escaping from the air bleed hole. If not, clear the hole of any deposits 

or debris.

9. If the pump is functioning as intended, pump is ready for use. Disconnect power from the pump if 

removing it from a test reservoir.

High voltages capable of causing severe injury or death by electrical 

shock are present in this unit.

• Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device if 

required by code.

Risk of bodily injury, electric shock, or equipment damage.

• Manual, continuous pump operation should be used only for emergencies, or when a large volume of water is to 

be pumped. The pump must be continuously monitored during operation and disconnected from power before 
the pump runs dry.

Risk of damage to pump or other equipment.

• If pump is run dry, it may damage pump and will void the warranty.
• Do not let the unit freeze. This may cause cracking or distortion that may destroy the unit.

Содержание WSV50HM

Страница 1: ...uctions carefully to avoid injury and property damage Do not disassemble or repair unit unless described in this manual Refer to product data plate s for additional precautions operating instructions...

Страница 2: ...ate vicinity Equipment can start automatically Always unplug the pump power cord and disconnect the electrical power before ser vicing the pump or switch An inoperative or malfunctioning pump could le...

Страница 3: ...free length of cable START Scum Septic Tank Chamber In Flow Baffle Tank Vent Tank Basin size 1 5 5 m Union Discharge Pump Power Cord Check Valve Float switch piggyback plug automatic models only 2 5...

Страница 4: ...l a free flow check valve in the discharge line that will easily pass 3 4 solids 5 Tape the pump cords to the discharge piping with electrical tape 6 Add an air relief bleed hole to the pump s dischar...

Страница 5: ...essure 5 If there is a valve on the discharge hose be sure it is open 6 Fill the basin or test reservoir until the pump is fully submerged 7 Plug in the power cord 8 Make sure a stream of water is esc...

Страница 6: ...hold the volute to the motor housing 3 Separate the volute from the motor housing IMPORTANT Do not remove the motor housing bolts or screws 4 Clean the impeller and the volute passage 5 Be sure the im...

Страница 7: ...rated pump performance Inlet to impeller plugged Pull pump and clean Pump is air locked Remove pump and clean air bleed hole Pump does not deliver rated capacity Lift too high for pump Check rated pum...

Страница 8: ...ectric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com For technical assistance parts or repair please contact 10000009299 Rev 000 8 21 Copyright 2021 Franklin Electric Co Inc All righ...

Страница 9: ...lesiones y da os a los bienes No desarme ni repare la unidad salvo que est descrito en este manual Consulte las placas de caracter sticas del producto para obtener instrucciones de operaci n precaucio...

Страница 10: ...ble el ctrico de la bomba y desconecte la alimenta ci n el ctrica antes de realizar el mantenimiento de la bomba o del interruptor Una bomba que no funciona o funciona mal podr a provocar una inundaci...

Страница 11: ...Flujo de entrada De ector Respiradero del tanque Tama o del tanque letrina 1 5 pies 5 m Uni n Descarga Cable el ctrico de la bomba V lvula de chequeo Interruptor de otador con enchufe a cuestas modelo...

Страница 12: ...l nea de descarga que pase f cilmente s lidos de 3 4 pulgadas 1 91 mm 5 Fije los cables de la bomba y del interruptor a la tuber a de descarga utilizando cinta aislante 6 Agregue un orificio de purga...

Страница 13: ...scarga aseg rese de que la v lvula est abierta 6 Llene la cubeta o el dep sito de prueba hasta que la bomba est completamente sumergida 7 Enchufe el cable de alimentaci n 8 Aseg rese de que un chorro...

Страница 14: ...2 Retire los cuatro pernos y cuatro arandelasque fijan la voluta a la carcasa del motor 3 Separe la voluta del carcasa del motor IMPORTANTE No retire la cubierta de la carcasa del motor 4 Limpie el i...

Страница 15: ...bomba Entrada al impulsor obstruido Quite la bomba y l mpiela La bomba est obturada por aire Si est obstruido quite la obstrucci n del orificio de ventila ci n La bomba no cumple con la capacidad nomi...

Страница 16: ...Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Para la ayuda t cnica por favor p ngase en contacto 10000009299 Rev 000 8 21 Copyright 2021 Franklin Electric Co Inc Todos los derechos...

Страница 17: ...ou tout dommage mat riel Ne d montez pas et ne r parez pas l appareil si ces op rations ne sont pas d crites dans le pr sent manuel Le non respect des proc dures d installation ou d utilisation et de...

Страница 18: ...rouillage tiquetage avant d entretenir l quipe ment Une pompe inop rante ou d fectueuse pourrait entra ner une inondation des blessures corporelles ou des dommages mat riels Utilisez avec un contr le...

Страница 19: ...ntr e Chicane vent du r servoir Dimension du r servoir bassin 1 5 pi 0 5 m Raccord Refoulement Cordon d alimentation de la pompe Clapet de retenue Ensemble che prise d interrupteur otteur mod les auto...

Страница 20: ...i passera facilement solides de 1 91 mm 3 4 po 5 Enregistrez la pompe et changez des cordes la ligne de renvoi avec la bande lectrique 6 Cr ez un orifice de prise d air la tuyauterie de refoulement de...

Страница 21: ...t ne provoque la sortie du tuyau du bassin ou du r servoir d essai 5 S il y a une valve sur le tuyau de refoulement s assurer que la vanne est ouverte 6 Remplissez le bassin ou le r servoir d essai ju...

Страница 22: ...mpulseur et de la volute 1 D branchez l alimentation de la pompe 2 Retirez les quatre boulons et les quatre rondelles qui fixent la volute au bo tier du moteur 3 S parez la volute du bo tier du moteur...

Страница 23: ...eur est obstru e Retirez la pompe et nettoyez la La pompe est bloqu e par de l air Enlever la pompe et nettoyer le trou de purge d air La pompe ne fonc tionne pas sa capa cit nominale L l vation est t...

Страница 24: ...ic Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Droits d auteur 2021 Franklin Electric Co Inc Tous droits r serv s 1000000929...

Отзывы: