Little Giant PCP550 Скачать руководство пользователя страница 1

INTRODUCTION

This instruction sheet provides you with the information required 
to safely own and operate your Little Giant pump. Retain these 
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. Little Giant pumps are carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your pump carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please con-
tact the place of purchase. They will assist you in replacement or 
repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY 
AND/OR PROPERTY DAMAGE!  

SAFETY GUIDELINES

Your pump is an electrical product and caution should be used 
when handling the pool cover pump or its electrical cord. Small 
children or pets may require restraining devices to prevent them 
from entering wet areas surrounding the pump or its power supply 
connections.
When installing this electrical equipment, basic safety precautions 
should always be followed, including the following:
 1. 

WARNING:

 To reduce the risk of injury, do not permit children 

to use this product unless they are closely supervised at all 
times. This pump should not be used to drain the pool or spa 
cover if there are people in the water. This pump has been 
investigated for draining swimming pool or spa covers only.

 2. 

WARNING:

 Risk of electric shock. Connect only to a ground-

ing type receptacle protected by a ground-fault circuit inter-
rupter (GFCI). Contact a qualified electrician if you cannot 
verify that the receptacle is protected by a GFCI.

 3. 

WARNING:

 Do not bury cord. Locate cord to minimize contact 

with lawn mowers, hedge trimmers, and other equipment.

 4. 

WARNING:

 To reduce the risk of electric shock, replace  

pump that has a damaged cord immediately.

 5. 

WARNING:

 To reduce the risk of electric shock, do not use 

extension cord to connect unit to electric supply; provide a 
properly-located outlet.

 6. Never pump chemicals or corrosive liquids with this pump. 

This could damage the integrity of the enclosure and cause 
an electrical short. This pump has been evaluated for use with 
water only.

 7. Never pump gasoline or other low flash point fluids with this 

pump. Explosion or fire could result. This pump has been 
evaluated for use with water only.

 8. If service is required, proceed carefully. The pump and sur-

rounding areas may be covered with water. Never plug or 
unplug the device while standing in wet or damp surfaces. If 
necessary, remove power at the breaker panel or have certi-
fied electrician remove power before attempting to service. 
Serious or fatal shocks could result if proper procedures are 
not followed. 

a)   Disconnect the power at the main electrical service box by 

switching the appropriate circuit breaker or removing fuse. 
In applications where screw type fuses are used, remove 
only with one hand while other hand or torso are free from 
contact with anything. Do not stand in water and do not 
touch any other conductive surfaces.

b)   Remove pump cord plug only after the power to the supply 

outlet has been removed. See Service Instructions before 
proceeding.

 9. Remove pump when conditions will cause water to freeze. 

Freezing water may result in rupture to pump and could result 
in possible electrical short.

 

PUMP SPECIFICATIONS

VOLTS

AMPS

WATTS

GALLONS PER HOUR

SHUT-OFF

1'

3'

5'

115

1.1

58

500

400

300

8'

INSTALLATION

Do not energize pump (connect to power source) until pump is 
properly located on pool cover.
Be certain electrical outlet to be used meets the requirements 
of the National Electrical code, as well as local electrical codes, 
including grounding and GFCI protection. Also verify that outlet 
is properly sized and located for this pump. Your installation may 
require a certified electrician or plumber. See ELECTRICAL sec-
tion.
If necessary, check your plumbing codes to verify that final instal-
lation will be in compliance with their requirements.
  1. Remove the pump from the carton and install the hose adap-

tor to the pump discharge.

 2. Connect a garden hose to the hose adaptor. The free end of 

the discharge hose must be secured so that it cannot blow 

back onto the pool cover in high wind.

 3. Gently lower pump onto the pool cover by holding on to 

the garden hose. Be certain that you do not pull power cord 

plug onto pool cover. Use garden hose to position pump on 

the pool cover. It is recommended that two people position the 

pump. One person should hold onto electrical cord plug while 

second person positions pump at desired location on pool 

cover. Once in position, the pump is ready for testing. See 

ELECTRICAL section.

NOTE:

 Become familiar with the SAFETY GUIDELINES. During 

the rainy season, you should check daily to see that your pump is 
functioning properly. Also, if you experience high winds or exces-
sive movement of the pool cover, be certain that the power supply 
cord has not been pulled onto the cover and that the pump is still 
oriented with the discharge hose properly positioned. If you plan 
to be away from your pool for extended periods of time, it is rec-
ommended that a friend or neighbor periodically check your pool 
cover pump and verify that everything is still functioning properly. 
Be sure to review the SAFETY GUIDELINES and ELECTRICAL 
sections with them!

1

PCP550

POOL COVER

PUMP

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

888.956.0000 • Fax: 405.947.8720

www.LittleGiantWater.com

[email protected]

Отзывы: