Little Giant CP1-115 Скачать руководство пользователя страница 1

BEFORE GETTING STARTED

OPERATION

SERVICE INSTRUCTIONS

ELECTRICAL CONNECTIONS

CP1-115, CP1-230, CP2-115, CP2-230, CP3-115, CP3-230

Evaporative Cooler Pumps

Pompes à refroidisseur à évaporation

Bombas para el enfriador evaporativo

Franklin Electric

301 N. MacArthur

Oklahoma City, OK 73127

DO NOT USE TO PUMP FLAMMABLE OR 

EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL 

OIL, KEROSENE, ETC.  DO NOT USE IN EXPLOSIVE ATMOSPHERES 

OR HAZARDOUS LOCATIONS AS CLASSIFIED BY THE NEC, ANSI/

NFPA70. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN 

PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. DO NOT 

HANDLE A PUMP OR PUMP MOTOR WITH WET HANDS OR WHEN 

STANDING ON A WET OR DAMP SURFACE, OR IN WATER.  FAILURE 

TO FOLLOW THIS WARNING CAN RESULT IN FATAL ELECTRICAL 

SHOCK. PUMP SHOULD ONLY BE USED WITH LIQUIDS COMPATIBLE 

WITH PUMP COMPONENT MATERIALS.

•  RISK OF ELECTRIC SHOCK The pump is supplied with a grounding 

conductor and/or grounding type attachment plug, to reduce the 

risk of electrical shock. Be certain that it is connected to a properly 

grounded grounding type receptacle.

•  Do not handle pump with wet hands or when standing on a wet or 

damp surface, or in water.

•  Do not pick up the pump by the power cord.

•  This equipment should be installed by technically qualified personnel. 

Comply with national and local electrical and plumbing codes as well 

as the National Electrical Code (NEC) and the Occupational Safety 

and Health Act (OSHA) when installing this unit. Failure to install it 

in compliance with national and local electrical and plumbing codes 

and within Franklin Electric recommendations may result in electrical 

shock or fire hazard, unsatisfactory performance, or equipment failure. 

Installation information is available through pump manufacturers and 

distributors, or directly from Franklin Electric at our toll-free number 

1-800-701-7894.

•  To reduce risk of electric shock which can result in personal injury, 

death or major property damage if ignored, be certain that this pump is 

connected to a circuit equipped with a ground fault circuit interrupter 

(GFCI) device. Comply with all national and local electrical and 

plumbing codes when installing this unit. Do not use extension cord.

•  Make certain that the unit is disconnected from the power source 

before attempting to service or remove any component. If the power 

disconnect is out-of-sight, lock it in the open position and tag it to 

prevent unexpected application of power.

READ THESE INSTRUCTIONS CAREFULLY 

BEFORE ATTEMPTING TO INSTALL, 

OPERATE, OR SERVICE OUR LITTLE GIANT PRODUCT. KNOW THE 

PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS 

COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

Shut off electrical power at fuse box before 

making any connections. If the electrical power 

disconnect is out-of-sight, lock it in the open position and tag it to 

prevent unexpected application of power.
1. Check the pump label for proper voltage required. Do not connect to 

voltage other than that shown.

2. If pump is supplied with a 3-pronge electrical plug, the third prong is 

to ground the pump to prevent possible electrical shock hazard. 

DO NOT REMOVE the third prong from the plug. If the plug is cut-

off or the cord is shortened, this action will void the warranty.

MAKE CERTAIN THAT THE UNIT IS 

DISCONNECTED FROM THE POWER SOURCE 

BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT!
1. This motor is permanently lubricated. Oiling is not required.
2. Periodically remove the bottom plate which is pressed onto the 

pump base. Lightly clean any corrosion or debris which may clog 

the impeller or pump cavity. Make sure the O-ring is positioned in 

bottom plate before re-installing.

3. Turn the impeller by hand to make sure it turns freely. Set pump 

down so you are not touching pump and impeller is not touching 

anything. Plug the unit into GFCI circuit for 10 seconds to see if the 

impeller turns; a) If it is rotating and GFCI did not trip, un-plug unit 

and install parts in reverse order in which they were removed. b) If it 

does not rotate, if pump is tripping circuit breakers, or not operating 

properly after cleaning, the pump should be replaced with a new 

unit. DO NOT attempt repairs yourself.

4. Be certain power cord is in good condition and contains no nicks or cuts.

1. This is NOT a submersible pump. DO NOT allow water or water 

spray to enter the motor housing. Water level should not exceed 3”.

2. Pump should be positioned as far from cooler pads or water source 

as possible to prevent water damage to the pump motor.

3. Ensure that the pump is sized to match the CFM air flow of the 

cooler, per below chart.

MODEL

CFM

CP1

5,000-7,500

CP2

7,500-15,000

CP3

15,000-21,000

4. The cooler pump is designed for use with many existing evaporative 

cooling units. If the evaporative cooler’s mounting bracket does not 

fit this pump, a piece of metal strap can be attached by removing a 

single screw located on the top cover. The pump must be attached 

by some means to prevent the pump from falling over and allowing 

water to enter the motor housing. Observe method of mounting and 

install replacement in same manner as original pump.

5. An additional screen or strainer around the pump base will help prevent 

particles or debris from clogging the impeller or discharge line.

6. Route the power supply cord of the pump in same manner as was 

done in the original installation.

•  Keep work area clean, well-lit, and uncluttered.

•  Keep safety labels clean and in good condition. 

•  Wear safety glasses while installing or performing maintenance on pump.

•  Make sure all ELECTRICAL POWER IS OFF before connecting any 

electrical wires. Wire pump system for correct voltages. Follow all 

pump wiring instructions provided in the “Electrical Connections” 

section of this manual.

•  This equipment must not be used by children or persons with 

reduced physical, sensory or mental abilities, or lacking in experience 

and expertise, unless supervised or instructed. Children may not 

use the equipment, nor may they play with the equipment or in the 

immediate vicinity.

•  In any installations where property damage and/or personal injury 

might result from an inoperative or leaking pump due to power 

outages, discharge line blockage, or any other reason, a backup 

system(s) (e.g. auxiliary switch) and/or alarm should be used.

•  Periodically inspect pump and system components.  Regularly check 

hoses for weakness or wear, making certain that all connections are 

secure. Schedule and perform routine maintenance as required and 

in accordance with the Service Instruction section.

GETTING STARTED

This instruction sheet provides you with the information required 

to safely own and operate your Little Giant pump. Retain these 

instructions for future reference. The Little Giant pump you have 

purchased is of the highest quality workmanship and material and 

has been engineered to give you long and reliable service. Little 

Giant pumps are carefully tested, inspected, and packaged to ensure 

safe delivery and operation. Please examine your pump carefully to 

ensure that no damage occurred during shipment.  If damage has 

occurred, please contact the place of purchase. They will assist you in 

replacement or repair, if required.

Form 998208   Rev.001   05/18

For technical assistance, please contact.  .  .  .  800 .701 .7894

www.littlegiant.com

[email protected]

E

Содержание CP1-115

Страница 1: ... base Lightly clean any corrosion or debris which may clog the impeller or pump cavity Make sure the O ring is positioned in bottom plate before re installing 3 Turn the impeller by hand to make sure it turns freely Set pump down so you are not touching pump and impeller is not touching anything Plug the unit into GFCI circuit for 10 seconds to see if the impeller turns a If it is rotating and GFC...

Страница 2: ...hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances 11 Products in which the pump has been used to pump or circulate anything other than fresh water at room temperature 12 Products in which the pump was allowed to operate dry fluid supply cut off 13 Products in which the sealed motor housing has been opened or the product has been otherwise dismantled by cus...

Страница 3: ...ourne librement Placer la pompe de façon à ne pas la toucher et de façon à ce que l impulseur ne touche à rien Brancher l unité dans un circuit GFCI pendant 10 secondes pour voir si l impulseur tourne a s il tourne et que le disjoncteur de fuite de terre GFCI ne s est pas déclenché débrancher l unité et installer les pièces dans l ordre inverse dans lequel elles ont été retirées b s il ne tourne p...

Страница 4: ...e plâtre boue goudron hydrocarbures dérivés d hydrocarbure huile essence solvants etc ou autres substances abrasives ou corrosives 11 Produits dont la pompe a pompé ou fait circuler autre chose que de l eau douce à la température ambiante 12 Produits dont la pompe a fonctionné à vide alimentation en fluide coupée 13 Produits dont le boîtier scellé du moteur a été ouvert ou qui ont été démontés d u...

Страница 5: ... en el orden inverso al orden en que se retiraron b si no gira si la bomba hace que se disparen disyuntores automáticos o no funciona correctamente después de la limpieza la bomba debe reemplazarse con una nueva unidad NO intente hacer reparaciones usted mismo 4 Asegúrese de que el cable de alimentación esté en buenas condiciones y no tenga cortes ni rasguños 1 Esta NO es una bomba sumergible NO p...

Страница 6: ...rava cemento grasa yeso lodo alquitrán hidrocarburos derivados de hidrocarburos aceite gasolina solventes etc u otras sustancias abrasivas o corrosivas 11 Productos en los que se haya usado la bomba para bombear o circular cualquier sustancia que no sea agua dulce a temperatura ambiente 12 Productos en los que se haya permitido que la bomba funcione en seco suministro de fluidos cortado 13 Product...