INTRODUCTION

This instruction sheet provides you with the information required to safely own and 

operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and 

material, and has been engineered to give you long and reliable service. These 

products are carefully tested, inspected, and packaged to ensure safe delivery 

and operation. Please examine your item(s) carefully to ensure that no damage 

occurred during shipment. If damage has occurred, please contact the place of 

purchase. They will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PRODUCT. KNOW 

THE PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD 

RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

SAFETY GUIDELINES

Disconnected the pump from the power source before servicing or removing any 

component.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, 

kerosene, etc. Do not use in explosive atmospheres. Pump should only be used 

with liquids compatible with pump component materials.
Do not handle pump with wet hands or when standing on a wet or damp surface 

or in water.
This pump is supplied with a grounding conductor and/or grounding type 

attachment plug. To reduce the risk of electric shock, be certain that it is 

connected to a properly grounded grounding type receptacle.
In any installation where property damage and/or personal injury might result from 

an inoperative or leaking pump due to power outages, discharge line blockage, 

or any other reason, a backup system(s) and/or alarm should be used.
Support pump and piping when assembling and when installed. Failure to do so 

may cause piping to break, pump to fall, motor bearing failures, etc.
If pump is oil-filled, the motor housing is filled with a dielectric lubricant at the 

factory for optimum motor heat transfer and lifetime lubrication of the bearings. 

Use of any other lubricant could cause damage and void the warranty. This 

lubricant is non-toxic; however, if it escapes the motor housing, it should be 

removed from the surface quickly by placing newspapers or other absorbent 

material on the water surface to soak it up, so aquatic life is undisturbed.
This pump has been tested using water only. The suitability of this pump for use 

with liquids other than water is the responsibility of the end-user.
This pump is not intended for permanent mounting to a building structure by 

bolting or similar means.

ELECTRICAL CONNECTIONS

  1.  Check the pump label for proper voltage required. Do not connect to voltage 

other than that shown.

  2.  If pump is supplied with a 3-prong electrical plug, the third prong is to ground 

the pump to prevent possible electrical shock hazard. DO NOT REMOVE the 

third prong from the plug. A separate branch circuit is recommended. Do not 

use an extension cord. Do not cut plug from the cord. If the plug is cut or the 

cord is shortened, then this action will void the warranty.

  3.  If the cord is equipped with stripped lead wires, such as on 230v models, 

be sure that the lead wires are connected to a power source correctly. The 

green/yellow wire is the ground, and the blue (or white) and the brown (or 

black) are live.

  4.  All wiring should be performed by a qualified electrician.
 5. DO NOT use sheet metal screws to secure the equipment grounding 

conductor.

CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY 

AND DISASSEMBLY OF YOUR PUMP.

OPERATION

  1.  This pump is designed to operate submerged or in-line. It can be placed in 

any position, but preferably the volute should be located to the side.

1

  2.  If the surface is dirt or sand, place pump on a flat surface such as a piece of 

wood or metal to prevent it from being clogged.

  3.  The weight of the pump must be supported adequately. DO NOT support the 

pump by the intake or discharge connections alone.

  4. Do not attempt to restrict the intake side of these pumps. Restricting the 

intake may cause damage to the seal and may starve the pump. If you 

require reduced flow rates, then place a valve on the discharge side of the 

pump or if flexible vinyl tubing is used, a clamp can be used on the tubing to 

restrict the flow.

  5.  Do not let the pump operate dry. It is designed to be cooled by pumping 

fluid. You may damage the seal and the motor may fail if the pump is allowed 

to run dry.

  6. If the pump is going to be idle for an extended period, follow the cleaning 

instructions outlined in the next section. Do not let the pump freeze in the 

wintertime. This may cause cracking or distortion that may destroy the 

pump.

  7.  If fused type plug is used on 230V units, a 2.0 amp fuse is recommended.

MAINTENANCE

DISCONNECT THE PUMP FROM THE POWER SOURCE BEFORE SERVICING 

OR REMOVING ANY COMPONENT!

  1.  This pump is permanently lubricated. Oiling is not required. DO NOT open 

the sealed portion of the pump or remove housing screws. The power cord 

cannot be replaced. In case of damage the entire pump must be replaced.

  2.  Periodic cleaning of the pump parts will prolong the life and efficiency of the 

pump. Refer to the assembly and disassembly of the pumping head.

  3. First remove the intake screen from the pump. Then remove the volute 

mounting screws. (DO NOT remove any other screws.)

  4. Lightly clean any corrosion or debris which may clog the impeller. Use a 

brush and penetrating oil and lightly scrape to remove encrusted material.

  5.  Turn the impeller by hand to make sure it turns freely. Set pump down so 

the pump and impeller are not touching anything. Plug the unit into GFCI 

circuit for 10 seconds to see if the impeller turns; a) If it is rotating and GFCI 

did not trip, unplug unit and install parts in reverse order in which they were 

removed. b) If it does not rotate, if pump is tripping circuit breakers, or not 

operating properly after cleaning, return to Proven Pump or its authorized 

service center. DO NOT attempt repairs yourself.

  6.  Be certain power cord is in good condition and contains no nicks or cuts.
  7.  The motor is a continuous-duty type, sealed in oil with an automatic thermal 

overload protector device.

   WARNING: THE PUMP MOTOR IS EQUIPPED WITH AN 

AUTOMATIC RESETTING THERMAL PROTECTOR AND MAY RESTART 

UNEXPECTEDLY. PROTECTOR TRIPPING IS AN INDICATION OF 

MOTOR OVERLOADING AS A RESULT OF OPERATING THE PUMP 

AT LOW HEADS (LOW DISCHARGE RESTRICTION), EXCESSIVELY 

HIGH OR LOW VOLTAGE, INADEQUATE WIRING, INCORRECT MOTOR 

CONNECTIONS, OR A DEFECTIVE MOTOR OR PUMP.

  8.  The pump can run against a restricted discharge such as a fountain without 

damage to the pump.

Figure 1

PUMP 

SERIES

REPAIR 

KIT

IMPELLER 

SPACING

DESCRIPTION

B-180

556704

.125"

Repair kit contains screen, screws, 

volute, gasket, and impeller.

B-240

B-300

556706

.045"

B-500

556705

.145"