   INTRODUCTION

This instruction sheet provides you with the information required to 
safely own and operate your Little Giant pump. Retain these 
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you long 
and reliable service. Little Giant pumps are carefully tested, inspected, 
and packaged to ensure safe delivery and operation. Please examine 
your pump carefully to ensure that no damage occurred during 
shipment. If damage has occurred, please contact the place of 
purchase. They will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE! 

SAFETY GUIDELINES

During installation, follow all local electrical and safety codes, as 
well as the National Electrical Code (NEC) and the Occupational 
Safety and Health Act (OSHA).
For maximum safety, this pump should be connected to a three-
prong grounded outlet equipped with a ground fault circuit 
interrupter (GFCI) device.
Do not use to pump flammable or explosive fluids such as 
gasoline, fuel oil, or kerosene. Pump should only be used with 
liquids compatible with pump component materials. 
Do not handle a pump or pump motor with wet hands or when 
standing on a wet or damp surface, or in water. Do not stand in 
water while changing fuses or insert your finger into the fuse socket. 
Failure to follow this warning can result in fatal electrical shock.

PUMP CONSTRUCTION

The Little Giant 2E-NDVR is designed for in-line use. The pump 
consists of an aluminum diecast housing, aluminum seal plate, 
nylon impeller and volute, stainless steel backplate, and Viton® 
gasket. The pump uses a two-seal design. The seals are double lip 
radial design type. One is mounted in the aluminum pump housing, 
the other is in the aluminum seal plate. The exposed motor shaft is 
stainless steel. The discharge is threaded (1/4” MNPT), the intake 
is also threaded (3/8” FNPT). An adapter is included for the intake 
for 1/2” ID tubing. 
The pump is designed for weak acids, mild chemicals, cleaning 
solvents, antifreeze, and potable fluids compatible with pump 
materials. 
The 2E-NDVR can be used submerged when pumping water or 
machine oils and should only be used in-line (not submerged) 
when pumping weak acids. This pump is not self priming; it must 
be installed so that the pump head (volute) is flooded when the 
pump is started. That is, the inlet of the pump must be below the 
level of the surface of the liquid being pumped (Figure 1). 

SERVICE INSTRUCTIONS

CAUTION: Before servicing the pump, disconnect it from electrical 
service by unplugging the power cord, removing the fuse, or 
turning off the disconnect box. 
 1.  If your pump fails to operate properly, remove it from water 

and try it at another electrical outlet to make sure that power is 
getting to unit. 

 2.  If the pump does not start:

 a)  Disconnect it from electrical service and remove the screen 

from the pump. 

 b)  Remove the 3 screws (item #5) in Figure 2. DO NOT remove 

any other screws.

 c)  Remove the volute.
 d) Lightly clean any corrosion or debris which may have 

clogged the impeller. Use a brush and penetrating oil and 
lightly scrape to remove encrusted material. 

 e)  Turn the impeller by hand to make sure that it turns freely.
  f)  Plug the unit in to see if the impeller will turn. 

 3.  If the pump operates properly, replace the parts in reverse 

order and test the unit in water. The unit should operate 
properly when connected to correct voltage. 

 4.  If the pump still does not operate properly, call your dealer or 

service person. 

DO NOT open the sealed portion of the unit or remove screws 
other than those indicated above. DO NOT cut the electric cord 
off short when removing the unit from the application. Disconnect 
the pump from its regular connections. Failure to follow these 
guidelines may void the warranty.  

2E-NDVR 

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]