INSTALLATION
Electrical Connections
7
Electrical Connections
Check the pump label for proper voltage required. Do not connect to voltage other than that
shown.
A ground fault circuit interrupter (GFCI) is required.
The pump should be connected or wired to its own circuit, with no other outlets or equipment in
the circuit line. The fuses and circuit breaker should be of ample capacity in the electrical circuit.
The 6EC-CIA-RF and 10EC-CIA-RF pumps have automatic switches with piggyback plugs on the
switch cords. For automatic operation, plug the pump cord into the float switch cord. Plug the float
switch cord (with pump cord attached) into the GFCI outlet.
Pump
HP
Voltage
Breaker Amps
6EC
1/3
115 V
15 A
10EC
1/2
115 V
15 A
Risk of severe injury or death by electrical shock.
•
Always disconnect the electrical power before touching the pump or discharge.
•
Check local electrical and building codes before installation. The installation must be in
accordance with their regulations as well as the most recent National Electrical Code (NEC).
•
The flexible jacketed cord assembly mounted to the pump must not be modified in any way,
with the exception of shortening the cord to fit into a control panel. Any splice between the
pump and the control panel must be made within a junction box mounted outside of the
basin and comply with the National Electrical Code. Employ a licensed electrician.
•
Do not use the power cord for lifting the pump.
•
Do not remove the third prong from the plug, or cut plug from cord. These actions will void
the warranty.
•
Do not use an extension cord.