Lithonia Lighting TWR2 Скачать руководство пользователя страница 1

SAVE THESE INSTRUCTIONS

2003  © Acuity Lighting Group, Inc., Rev B 08/09/07

RJ5210140

 

INST SHT TWR2

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

INSTALLATION

INSTRUCTIONS

RISK OF FIRE - Lamps are hot. Keep
combustible material away from hot
parts.

TROUBLESHOOTING

CAUTION

If this fixture fails to operate properly, check to
make sure:

The correct lamp is properly installed.

The fixture is wired correctly.

The lamp is not faulty.

The fixture is grounded correctly.

The line voltage at the fixture is correct.

Observe lamp manufacturer's recommendations
and restrictions on lamp operations, including but
not limited to ballast type, burning position, and
cycling.  Use ANSI rated lamps only.

Maintenance

: For optimum performance,

periodically clean reflector and lens with a soft,
damp cloth.

Important

DO NOT

 use abrasive materials, glass

cleaner or other solvents on lens or paint. Use only

mild, soapy water.

WARNING:

 FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH,

INJURY, OR SIGNIFICANT PROPERTY DAMAGE

 - For your protection, read and follow these warnings

and instructions carefully before installing or maintaining this fixture. These instructions do not attempt to
cover all installation and maintenance situations. If you do not understand these instructions or additional
information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.

WARNING:

 RISK OF ELECTRIC SHOCK - 

To avoid electric shock, serious injury, or death, be certain that

all electrical power is disconnected from the supply branch circuit conductors before installing or main-
taining this fixture. This product must be installed and maintained in accordance with the applicable instal-
lation codes by a person familiar with the construction and operation of the product and the hazards
involved.

WARNING: 

RISK OF PERSONAL INJURY - 

This product may have sharp edges. Wear gloves to

prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product.
Lithonia Lighting assumes no responsibility for claims arising out of improper or careless installation or
handling of this product.

IMPOR

IMPOR

IMPOR

IMPOR

IMPORT

T

T

T

TANT SAFETY INSTRUCTIONS

ANT SAFETY INSTRUCTIONS

ANT SAFETY INSTRUCTIONS

ANT SAFETY INSTRUCTIONS

ANT SAFETY INSTRUCTIONS

RISK OF FIRE - Observe lamp
manufacturer’s warnings, recommenda-
tions and restrictions on lamp operation
and maintenance.

WARNING

WARNING

WARNING

WARNING

WARNING

• Do not install a damaged fixture.

•   This fixture must be wired in accordance

with the National Electrical Code and
applicable local codes and ordinances.

• Proper grounding is required to ensure

personal safety.  Be certain green lead
from the fixture is connected to supply
ground.

• Use code compliant connectors for all

electrical connections.

• ALL work should be done by a qualified

electrician.

WARNING: 

 NEVER connect or disconnect

any component while power supply is
engaged.

DELIVERY

Upon receipt of fixture and accesso-

ries (packed separately), thoroughly inspect for
any freight damage.  All damage should be
reported to the delivery carrier.  Do not install
damaged fixtures.  Compare the catalog de-
scription listed on the packing slip with the fix-
ture label on the inside of the housing to be sure
you have received the correct merchandise.

IMPORTANT SAFETY

INSTRUCTIONS

WARNING

WARNING

WARNING

WARNING

WARNING

Wall Pack

Prior to Installation

Read carefully before installing light fixtures.  If you do not understand these instructions, please
contact your local Lithonia distributor before installing.

INSTALLATION

MOUNTING  - 

Wall pack is designed to allow for a variety of mounting configurations.  It can be

mounted directly to a recessed junction box or mounted directly to the wall for wiring via
surface conduit from either side or the top.  

DO NOT AIM UP .  NOT INTENDED FOR MOUNTING

INVERTED OR ON CEILING.

JUNCTION BOX MOUNTING

1.  Remove the lamp, reflector, and component cover and keep them in a safe place

.

2.  Look at the back of the rear housing to locate the pre-cast locators that match most
standard junction-box mounting locations.  Using a hammer and punch or drill, prepare the
housing by knocking out only the appropriate mounting holes, along with the center wiring
access hole.
3.  Install the provided self-adhesive gasket to the back of the fixture to cover the junction box.
4.  Align the back housing correctly and mount securely.
5.  Use code compliant connectors to connect fixture leads to supply leads, being careful to
follow the wiring directions below.
6.  Replace the component cover and reflector and install the lamp, being careful to follow the
re-lamping directions below.
7.  Replace front cover.  Make sure that the lens gasket is properly seated around the perimeter
of the cover to insure a weathertight seal.
8.  Make sure all wiring access holes are sealed with weatherproof silicone sealant.

NOTE:

  Fixture must be installed per all applicable national and local codes.

Отзывы: