BriteCor AC Direct
BCO/BWP Wallpack
Installation Manual
Страница 1: ...BriteCor AC Direct BCO BWP Wallpack Installation Manual ...
Страница 2: ...xture in a two wire system that is not grounded If dimming functionality is included use only with Litesheet approved dimmers This unit is not approved for use in ducted ceilings Do not use excessive force when manipulating cables and wires WARNING To prevent wiring damage or abrasion do not pinch wires between surfaces WARNING Only connect Luminaire to the voltage indicated by the Luminaire label...
Страница 3: ...wer source Installation 1 Open luminaire by loosening the two screws located on the side of the housing 2 Knock out drill holes in the rear housing for mounting fixture to wall and for securement to junction box j box not provided 3 Apply silicon sealant not provided to any unused holes to prevent water entry 4 Secure fixture to wall with two or more screws not provided 5 Secure fixture to junctio...
Страница 4: ...ded Connect the incoming line power to the luminaire disconnect provided Black Line Power Hot White Neutral Green Safety Ground 7 Close the luminaire lid and reinsert the machine screws Tighten the screws fully to ensure a tight seal For warranty information and technical support contact us at 434 446 1460 Find more great products at www litesheet com ...