EDX-B02D [EUM-B]
10
2-10 Motor Rotate Setting
STEP-1: On the main page, press
【
FCN
】
six times to enter motor operation status
setting. The cursor will blink:
STEP-2: Press
【▲】
or
【▼】
to select channel
STEP-3: Press
【
◀
】
or
【
▶
】
to shift to motor rotate setting status:
STEP-4: Press
【▲】
or
【▼】
to select UP/DOWN
In which:
UP — motor rotates clockwise
DOWN— motor rotates counterclockwise
STEP-5: Press
【
◀
】
or
【
▶
】
to shift to motor operation setting screen:
STEP-6: Press
【▲】
or
【▼】
to select motor rotate time(1-99s) or any one of infinity
STEP-7: After setting, press
【
DMX
】
to save, press
【
FCN
】
to exit.
2-11 Check Software Version
On the main page, press
【
FUNC
】
nine times to check the current software version.
Blink, channel 1
Blink, UP means motor rotates clockwise
Blink, motor operating time is 10s