background image

 

EDX-B02D [EUM-B]

                                                                                                                            9

 

 

STEP-2: Press

【▲】

or

【▼】

to select channel 

STEP-3: Press

or

to shift to LEVEL setting status of channel 

 

 

 
STEP-4: Press

【▲】

or

【▼】

to modify LEVEL 0-FL of channel 

 

 

2-8 Scene Save and Recall 

STEP-1: According to 2-7, press 

DMX

  to enter scene save screen: 

 

STEP-2: Press

【▲】

  or

【▼】

to select the desired scene No., and save the current 

channel status as any scene (SC1-6) 

             

 

STEP-3: After setting, press

DMX

to save, press 

FCN

to exit. 

2-9 Scene Duration Setting 

STEP-1: On the main page, press

FCN

four times to enter Scene Duration Setting. 

The cursor will blink: 

               

 

STEP-2: Press

【▲】

  or

【▼】

to select scene No., and can select any scene (SC1-6) 

               

 

STEP-3: Press

or

to shift to scene duration setting status: 

       

 

STEP-4: Press

【▲】

  or

【▼】

to select scene duration(1-99s) or any one of infinity. 

 

Blink, the current LEVEL is 50, the motor stops. 

Blink, the current LEVEL is 75, the motor 

rotates clockwise. 

 

Blink, scene 1

 

Blink, scene duration scene is 10s

 

 

Содержание EDX-B02D

Страница 1: ...EDX B02D EUM B 0 User Manual EDX B02D 2 Channel Curtain Controller...

Страница 2: ...on 5 2 2 DMX Address Setting 5 2 3 Motor Control 6 2 4 Accept Refuse DMX Signal 6 2 5 ID No Setting 7 2 6 Zone Setting 7 2 6 1 Single Multi Zone Setting 7 2 6 2 Single Zone Setting 7 2 6 3 Multi Zone...

Страница 3: ...se When the DMX value is in the range of 25 75 the curtain motor stop rotating 2 dry contacts output control the curtain motor rotate clockwise and counterclockwise Accept ECP control panel Can save 6...

Страница 4: ...EDX B02D EUM B 3 1 3 Dimension 1 4 Panel Introduction 11 1 2 3 4 5 7 10 0 9 6 8...

Страница 5: ...n FCN function button direction button 6 Power indicator 4 5 8 Signal input DMX 512 RS485 7 Communication indicator 9 Counterclockwise shortcut button and indicator 10 clockwise shortcut button and in...

Страница 6: ...ys STEP 2 Press DMX to initial STEP 3 then enter the main screen Press FCN after STEP 2 can stop initialization 2 2 DMX Address Setting Standard DMX console can output 512 channels and EDX B02D can us...

Страница 7: ...r Control On the main page hold to start the motor rotate clockwise hold to start the motor rotate counterclockwise release or the motor will stop rotating 2 4 Accept Refuse DMX Signal STEP 1 On the m...

Страница 8: ...FCN to exit 2 6 Zone Setting Definition of zone The device must set the Zone No before using which consists of two parts one is the zone no and another is the start channel address 2 6 1 Single Multi...

Страница 9: ...cursor will blink STEP 2 Press or can modify channel STEP 3 Press or to shift to zone select state The cursor will blink STEP 4 Press or can choose channel zone Up to 99 Zones STEP 5 Press or to shif...

Страница 10: ...ene SC1 6 STEP 3 After setting press DMX to save press FCN to exit 2 9 Scene Duration Setting STEP 1 On the main page press FCN four times to enter Scene Duration Setting The cursor will blink STEP 2...

Страница 11: ...t UP DOWN In which UP motor rotates clockwise DOWN motor rotates counterclockwise STEP 5 Press or to shift to motor operation setting screen STEP 6 Press or to select motor rotate time 1 99s or any on...

Страница 12: ...s control c Labor costs incurred in diagnosis of defects installation reinstallation wiring rewiring repairing adjustment or reprogramming of a product or any other consequential expenses d Other Lite...

Отзывы: