22/80
3.4.
Sound power level
WARNING
Danger of hearing damage
Wearing of hearing protection is prescribed from a sound power level of 85 dB(A).
Wear your personal hearing protection
The measured sound power level L
WA
93.5 dB(A)
The emission sound pressure at the workplace L
pA
amounts to:
COMPACTCUT 905 P/T
93.6 dB(A)
The guaranteed sound power level L
WA
amounts to:
COMPACTCUT 905 P/T
104 dB(A)
The values were determined by a sound emission measurement.
The examination took place in idle with the largest permitted saw blade of the floor saw.
Measurement tolerances:
2.5 dB for the A-weighted sound power level
4 dB for the A-weighted emission sound pressure level
The emission sound pressure level determination was carried out with consideration of the standards
EN ISO 3744, EN 13862 and directive 2000/14/EC.
3.5.
Hand arm vibration
WARNING
Danger through vibration
Vibration can lead to bone or joint damage as well as to blood circulation problems.
Take breaks regularly when working with the machine
The indicated value was determined with the maximum saw blade diameter of 1000 mm.
The effect can be inversely proportional to the weight of the operator.
Oscillation total value:
COMPACTCUT 905 P/TA
HV
below 2.5 m/s
2
During the measurements, the following standards were considered:
EN ISO 5349, VD 2057 sheet 2, directive 2002/42/EC.
The indicated values were measured when cutting concrete, with a cutting depth of 5 cm. This value is
affected in practice by the following conditions:
Quality of the saw blade - number of saw blades
Weight of the operator - feed speed
State of the machine - quality of the concrete