99
WWW.LCMETER.COM
LCI40
Series IOM
8 teChniCal data
Materials
Signal Converter Housing
Standard: die-cast aluminium (polyurethane coated)
Option: stainless steel 316 (1.4408)
Measuring Sensor
For housing material, process connections, measuring tubes, accessories and gaskets, refer
to technical data for the measuring sensor.
8.2 technical data
Electrical Connection
General
Electrical connection is carried out in conformity with the VDE 0100 directive “Regulations
for electrical power installations with line voltages up to 1000 V” or equivalent national
specifications.
Power Supply
Standard: 100 to 230 VAC (-15% / +10%), 50/60 Hz
Option 1: 24 VDC (-55% / +30%)
Option 2: 24 VAC/DC (AC: -15% / +10%, 50/60 Hz; DC: -25% / +30%)
Power Consumption
AC: 22 VA
DC: 12 W
Signal Cable
Only for remote versions.
10 core shielded cable. Detailed specifications are available on request.
Length: max. 65.6 ft / 20 m
Cable Entries
Standard: M20 x 1.5 (8 to 12 mm)
Option: ½ NPT, PF ½