92
WWW.LCMETER.COM
LCI40
Series IOM
7 ServiCe
danGer
Work on the signal converter
electronics may only be performed
when disconnected from the power
supply.
WarninG
Observe without fail the local
occupational health and safety
regulations. Any work done on
the electrical components of the
measuring device may only be
carried out by properly trained
specialists.
•
Remove the front panel. Use a small screwdriver to
open the plastic clips that hold the display.
•
Remove the 2 locking screws.
•
Carefully pull the electronics almost completely out
of the housing.
•
Remove the 2 connecting cables from the electronics
before removing the signal converter electronics to
be replaced.
•
To insert the new electronics, first connect the two
connecting cables to the electronics.
•
Carefully push the electronics back into the housing.
•
Tighten the two locking screws again and secure
the display. The measuring system recognises the
hardware replacement when the power supply is
switched on.
7.1 replacing the Signal Converter electronics