25
WWW.LCMETER.COM
LCI40
Series IOM
4.8.3 Status output and limit Switch
•
The status outputs / limit switches are electrically
isolated from each other and from all other circuits.
•
The output stages of the status outputs/limit
switches during simple active or passive operation
behave like relay contacts and can be connected
with any polarity.
•
All operating data and functions can be adjusted.
•
Passive mode: external power supply required:
U
ext
≤
32 VDC; I
≤
100 mA
•
Active mode: use of the internal power supply:
U
nom
= 24 VDC; I
≤
20 mA
•
For information on the adjustable operating states
refer to Function tables on page 46.
4.8.4 Control input
•
All control inputs are electrically isolated from each
other and from all other circuits.
•
All operating data and functions can be adjusted.
•
Passive mode: external power supply required:
U
ext
≤
32 VDC
•
Active mode: use of the internal power supply:
U
nom
= 24 VDC
•
For information on the adjustable operating states
refer to Function tables on page 46.
4. eleCtriCal ConneCtionS
information
For further information refer to
Description of the inputs and
outputs on page 25 and refer to
technical data on page 96.
danGer
For devices used in hazardous
areas, additional safety notes
apply.
information
Depending on the version, the
pulse and frequency outputs must
be connected passively or actively.
Which I/O version and inputs/
outputs are installed in your signal
converter are indicated on the
sticker in the cover of the terminal
compartment.
4.8 description of the inputs and outputs