20
WWW.LCMETER.COM
LCI40
Series IOM
4. eleCtriCal ConneCtionS
4.7.2 description of the CG number
The last 3 digits of the CG number (5, 6 and 7) indicate
the assignment of the terminal connections. Please
refer to the following examples.
Marking (CG Number) of the Electronics Module and Input/
Output Variants
1. ID number: 3
2. ID number: 0 = standard; 9 = special
3. Power supply option
4. Display (language versions)
5. Input/output version (I/O)
6. 1st optional module for connection terminal A
7. 2nd optional module for connection terminal B
The last 3 digits of the CG number (5, 6 and 7) indicate
the assignment of the terminal connections. Please
refer to the examples.
CG Number Examples
CG 330 11 100
100 to 230 VAC & standard display;
basic I/O: I
a
or I
p
& S
p
/C
p
& S
p
& P
p
/
S
p
CG 330 11 7FK
100 to 230 VAC & standard display;
modular I/O: I
a
& P
N
/S
N
and optional
module P
N
/S
N
& C
N
CG 330 81 4EB
24 VDC & standard display; modular
I/O: I
a
& P
a
/S
a
and optional module
P
p
/S
p
& I
p
Description of Abbreviations and CG Identifier for Possible Optional Modules on Terminals A and B
Abbreviation
Identifier for CG No. Description
I
a
A
Active current output
I
p
B
Passive current output
P
a
/ S
a
C
Active pulse output, frequency output, status output or limit switch (changeable)
P
p
/ S
p
E
Passive pulse output, frequency output, status output or limit switch (changeable)
C
a
G
Active control input
C
p
K
Passive control input
-
8
No additional module installed
-
0
No further module possible
4.7 inputs and outputs, overview