Lippert Components Schwintek In-Wall Скачать руководство пользователя страница 1

Page 1

June 17, 2014 10:35 AM

Contact us: Lippert Components Inc. - www.lci1.com/customerservice - Phone: (574) 537-8900 - Email: [email protected]

0272

LIP Sheet -0272

SLIDEOUTS

SCHWINTEK IN-WALL

 SLIDEOUT TROUBLESHOOTING 

AND COMPONENT REPLACEMENT

Troubleshooting

Error Codes

During operation when an error occurs, the board will use the LEDs to indicate where the problem exists. 

For motor specific faults, the green LED will blink once for Motor 1, and two times for Motor 2. The red LED 

will blink from two to nine times, depending on the error code.
The error codes are as follows: 
2  

Battery drop out:

 Battery capacity low enough to drop below 6 volts while running.

3  

Low battery: 

Voltage below 8 volts at start of cycle. 

4  

High battery:

 Voltage greater than 18 volts. 

5  

Excessive motor current:

  High amperage, also indicated by one side of slide continually stalling. 

6  

Motor short circuit:

 Motor or wiring to motor has shorted out. 

8  

Hall signal not present: 

Encoder is not providing a signal. Usually a wiring problem. 

9  

Hall power short to ground:

 Power to encoder has been shorted to ground. Usually a wiring problem. 

In the event of any error code, the unit can be manually overridden electronically using these steps:

1. 

Locate the circuit board (brain, controller).

2. 

Press the “mode button” six times quickly, press a seventh time and hold for approximately five 

seconds. 

3. 

The red and green LED lights will begin to flash indicating you are in override mode.

4. 

Using the wall switch, press and hold the “in” button until the unit comes completely in.

NoTE: 

The "8" error code is the most common. This can signify one of these issues:

• 

Pinched or broken wiring in the system harness or motor pigtail.

• 

Disconnected or faulty motor.

NoTE: 

The "9" error code signifies a short in the red or black wire on the motor. Replace the motor.

Checking Fuses

Check the 12 volt fuse box for blown fuses, and replace any if necessary. If the fuse blows immediately upon 

replacement, there is a problem with the wiring to the circuit board. Have qualified service personnel check 

and repair. 

Obstructions

Check outside the RV for possible obstructions: tree, post, car, folded over flap seals, debris on top of the 

slide room, etc. Check inside the RV for any obstructions: luggage, furniture, open cabinets, carpeting, 

etc. Also check for smaller objects that may be wedged under the floor or in the sides of unit. Remove 

obstructions before proceeding. 

Содержание Schwintek In-Wall

Страница 1: ...roblem In the event of any error code the unit can be manually overridden electronically using these steps 1 Locate the circuit board brain controller 2 Press the mode button six times quickly press a seventh time and hold for approximately five seconds 3 The red and green LED lights will begin to flash indicating you are in override mode 4 Using the wall switch press and hold the in button until ...

Страница 2: ...lp A If only one side of the room is moving then with someone s assistance press the switch to extend or retract the room while pushing the non moving side in the appropriate direction On larger rooms it may be necessary to have two or more people pushing the room Q Non moving side moved manually A Try to push the non moving side in and out If a motor shaft has broken then it will be possible to m...

Страница 3: ...itch Component Replacement Procedure Tools Required OEM Recommended Sealant Cordless screw gun Rubber mallet 2x4 length gap between T molding and side of unit 1 4 Razor knife Floor jack 1 Extend the slide room until about of the room is left inside the unit 2 Jack up one side of the slide room just enough to hold its weight Fig 1 3 Place the 2x4 block on top of the slide room standing on its edge ...

Страница 4: ... Slide Room Upper Gear Rack 10 Pan Head Screws Fig 3 11 You may need to pry the gear racks away from the sides of the slide room with a flathead screwdriver or putty knife Do this carefully so you don t damage the finish on the side of the slide room 12 Carefully slide the ends of the gear racks past the bulb seal on the T molding 13 Pull the full system out and set aside 14 Prepare the slide room...

Страница 5: ... contact the side face of the unit 17 Remove the shipping angles from the system Fig 4A 18 Gently slip the system through the opening between the slide room and the side wall opening Tuck the gear racks inside the bulb seal attached to the T molding 19 Align the bottom lip of the lower gear rack with the bottom edge of the slide room Fig 5 Fig 4 Slide Room A Fig 5 Lower Gear Rack Alignment Flange ...

Страница 6: ...n and secure all the gear racks put all the screws in to the gear racks 23 Attach the jumper wires to the motor in top of the slide column and then to the drill battery Actuate the motor to move the slide column in towards the coach Stop it when it is still a few inches away from the unit Remove the jumper cable 24 Make sure the motor cable is tucked into the top of the slide column 25 Remove the ...

Отзывы: