Troubleshooting
For leveling system concerns, refer to the Leveling System Troubleshooting Chart.
Error Mode
Leveling System Troubleshooting Chart
What Is Happening?
Why?
What Should Be Done?
System will not turn on
and On/Off indicator light
does not illuminate.
Coach ignition not in RUN position.
Turn ignition to RUN position.
Parking brake not set.
Set parking brake.
Controls have been on for more
than four minutes and have
timed out.
Turn ignition OFF and then back ON.
Control panel turns on but
turns off when jack button
is pushed or displays
"Low Voltage."
Low voltage on battery.
Start coach to charge battery.
Control panel turns on,
coach will not auto level,
"Jacks Down" displayed,
jacks are retracted.
Low fluid level.
Change fluid level in reservoir. If fluid is low, add fluid
to 1/2" from top of reservoir with jacks retracted. If
JACKS DOWN light remains on, call Lippert Service.
Jacks will not extend to
ground, pump is running.
Little to no fluid in reservoir.
Add fluid as recommended.
Leg valve is inoperative.
Clean, repair or replace.
Electronic signal is lost between
control and leg valves.
Trace wires for voltage drop or loss of signal. Repair or
replace necessary wires or replace touchpad.
Any one or two jacks will
not retract.
Hose damaged or unconnected.
Replace with new hose or reconnect hose.
Valve inoperative.
Replace inoperative valve.
Electronic signal is lost between
control and solenoid.
Attempt to retract jacks in MANUAL mode. If
successful, replace touchpad. If not, test for voltage
drop between touchpad and leg valve. Repair bad
wiring or replace defective board or valve.
"Jacks Retracted" does
not display when all jacks
are retracted.
Low fluid level.
Add fluid as recommended.
Retract press switch inoperable.
Check connection or replace.
Alarm sounds and "Jacks
Down" light starts flashing
while traveling, jacks are
fully retracted.
Low fluid level.
Add fluid as recommended.
Retract press switch inoperable.
Check connection or replace.
Jack bleeds down after
being extended.
Valve Manual Override open.
Close override.
Touchpad powers
up, screen displays
"Low Voltage."
Engine not running.
Start coach engine.
No power to touchpad.
Tripped circuit breaker.
Reset.
Ignition not ON.
Turn ignition ON.
Auto level function does
not finish.
Error code "Unable to
Finish Leveling."
Move coach to a more level site.