Operating Manual
Cross-flow fan unit type GSG-NV1 / 2
29 - 64
010980-26-E BA GSG-NV1_2 / 23.03.2012
15.4. Nozzle selection and distribution quantity
The
LIPCO GSG-NV
is equipped with green ALBUZ AVI 80° flat
fan venture nozzles. (Other nozzles are available on request.)
Fig. xx
During installation make sure
that the seal is properly
mounted before the fan noz-
zle.
Seal
It is recommended that the
nozzle body be swiveled up-
ward for assembly in perpen-
dicular position.
Determining the distribution quantity in l/min. from nozzle inserts
in drip-stop nozzle bodies.
Distribution
quantity of
one nozzle
in l/m
Driving
speed
Row
spacing
Expended
quantity
Number of
Tunnel
=
(km/h)
x
(m)
x
l/ha
x
(units)
600
x
Number of all open nozzles
The choice of required nozzles is based on the following nozzle
charts. For the same nozzles, the discharge of liquid from the
LIPCO GSG-NV
corresponds to the product of the number of
nozzles X single nozzle discharge.
ALBUZ AVI 80° flat fan venturi nozzle
(1 bar = 0.0689 lbf/in²)
bar
7
8
9
10
12
14
16
orange
0,61
0,65
0,69
0,73
0,80
0,86
0,92
grün
0,92
0,98
1,04
1,09
1,20
1,29
1,38
gelb
1,22
1,31
1,39
1,46
1,60
1,73
1,85
lila
1,53
1,63
1,73
1,82
2,00
2,16
2,31
If the unit is equipped with different nozzles, the discharge of all
single nozzles must be added together. Please note that oppos-