Operating instruction
Saddle-mount fan unit with tank trailer GSG-AN-VM
50 - 72
011170-05-EN BA GSG-AN-VM / 2019-01-16
Note:
•
This ball valve is also used for quick cleaning of pressure filter 1.
Closing this ball valve too much will have a negative influence on
quick cleaning process for pressure filter 1.
•
That means, it is important to find a good balance between low
tendency of foaming and good quick cleaning result.
•
For full electrical version, mixing unit will be switched via control
box.
•
Then fill the plant protection agent in the filling strainer and flush
in via the flushing mechanism.
Flushing device / Filler strainer:
•
Filler strainer with integrated
flushing device.
Filler strainer
Shut-off valve for flushing de-
vice, on top of spray liquid tank
– manually operated.
Fig. 30
•
Water-soluble granulates should be added directly over the wa-
ter surface in the spray liquid tank, mixing well.
•
Note:
Do not flush in granulates via the filler strainer, because they
tend to clump and can stop up the filling strainer.
•
Clean empty plant protection agent containers and dispose of in
accordance with legal regulations. Cleaning liquid can be added
to the spraying liquid for this purpose.
•
Then fill spray liquid tank with water to the calculated level.