Operating instruction
Saddle-mount fan unit with tank trailer GSG-AN-VM
36 - 72
011170-05-EN BA GSG-AN-VM / 2019-01-16
•
Switch off the
GSG-AN-VM
and fill the tank again up to the se-
lected marking on the filling mandrel.
•
Make a spray test for at least 2 min.
•
Calculate the volume of liquid used by refilling to the marking
and then compare with the calculated total discharge.
For smaller output volumes or to increase the accuracy of the
measurement, spray for a longer time.
•
In case of deviations, correct the spray pressure and repeat the
procedure. Higher pressure results in greater output of liquid and
vice versa.
•
Record the results in writing.