The smoke generator was designed to need very little maintenance.
Yearly maintenance
Once a year, the smoke generator needs to be flushed with distilled water. First all smoke liquid must
be removed from the generator. Once this done, 3 litres of distilled water needs to be flushed through
the whole system. Start the generator and leave it running on continuous until all liquid is vaporized.
Should any liquid remain it needs to be manually removed.
Warranty
The smoke generator has a full one year warranty on materials, hourly rates and call -out
charges. Any damage caused by wrong use, fall damage or other external factors are not
covered by the warranty.
The warranty will immediately be voided if other liquids other than the ones sold by LION are used.
The warranty starts the second the generator leaves LION Fire Training Products.
Water
The generator is
not
water tight. If the generator is used during fire trainings make sure it is placed in
a spot where it cannot get wet. It cannot be covered with a sheet. This can have dangerous
consequences if the generator cannot discharge any heat.
When using outside, be mindful of weather conditions!
De warranty is voided if damage is caused by water.
Cleaning spilled smoke liquid
Should you spill any liquid next to or on the generator, this can be cleaned by a moist tow el.
Connecting cable
Should the connecting cable need replacing, the following should use:
-
230V: Euro connecting cable with H05VV-F (VMVL) specification or better. It should have
core diameter of 3 x 1 mm
2.
-
115V: 14AWG x 3 or better, IEC320-C19 and NEMA 5-15P plug.
Opening and repairing
Opening and repairing of the generator may only be done by qualified personnel.