The standard M-Fire console requires no special maintenance. 

However, the battery should be kept 

charged.

 If the battery is empty, it should be recharged immediately by connecting the control panel to 

the mains electricity and pulling out the emergency stop switch. The console may remain connected to 

the mains once the battery is fully recharged. 

 

Resolving faults 

Check the gas hoses condition 

before each use

. If leaks are detected, immediately turn off the gas 

supply and ensure that repairs are carried out.

 

 

An internal fault in the electronics is indicated by the rapid blinking of the 'Fail' LED for as long as this fault 

is unresolved. Operation is not possible! 

 

In cases of overheating in the flame detection sensors, the 'Fail' LED will flash until the temperature has 

returned to normal. Operation is not possible! 

 

If the start button is pressed during the occurrence of an error, an acoustic signal will be sound (fast 

beeping) for as long as the button is pushed in. 

In cases of overheating, a waiting period is activated until the system releases itself. 

If further errors occur, contact LION. 

 

If the mains electricity cable of the standard M-Fire console is to be repaired or replaced, use a 3-core 

rubber flex with a core diameter of 1 mm

2

 and the specification H07RN-F.

 

 

Guarantee

 

  LION will replace any part of the “M-Fire Unit” in case the malfunctioning is a result of a material or 

construction fault, within 12 months after the original purchase date. 

  LION will not take any responsibility for any damage caused by using or defects concerning the “M-

Fire Unit.” 

  In case of defects or damages, in which has been established that the operating and maintenance 

instructions have not been followed, or, as a result of rough and / or unjustified handling, any claim 

regarding to LION will be denied. 

  The warranty will be invalid when using powder extinguishing agents. 

 

 

Содержание M-FIRE

Страница 1: ...Version 1 2 14 01 20 USER S MANUAL M FIRE UNITS ORIGINAL USER S MANUAL ...

Страница 2: ...M Fire Units User s Manual Version 1 2 14 01 20 Page 1 Contents System description 2 Use of the M Fire Unit 4 Specifications 7 Important remarks 8 ...

Страница 3: ...ot of extra maintenance and cleaning The standard M Fire operation console has wheels and handles to aid transportation When used in a practice building or another project based construction it is sometimes possible to integrate the controls instead of using the standard console The M Fire burner units are intended for installation in fixed locations If this is in an enclosed space you must take t...

Страница 4: ...ocated on the control console The standard operation console can be used in locations without a mains power supply as it is equipped with a battery Safety aspects The control desk contains an emergency stop switch If this switch is pressed the electrical supply mains voltage and low voltage supply will be interrupted The burner unit of the M Fire operates on a safe voltage of 12 Volts DC The contr...

Страница 5: ...eration of M Fire Unit can be carried out in 2 different ways By means of the selector switch hand or auto can be chosen Hand manual The instructor determines the operation by holding down the start button The M Fire Unit will ignite automatically by means of an electrical ignition Acoustic signal prior to the start 4 beeps of approx 0 3 seconds with the same length of time in between Next the fir...

Страница 6: ...nguished detected by sensors or by releasing start button the gas supply shuts off and an acoustic sound will be produced a long beep of approx 1 5 seconds This single long beep is the safe signal In case of an emergency the system can be shut down by pushing the emergency stop switch switching off the power switch or shutting off the gas valve spherical plug Always close the gas valve on the gas ...

Страница 7: ...is not possible If the start button is pressed during the occurrence of an error an acoustic signal will be sound fast beeping for as long as the button is pushed in In cases of overheating a waiting period is activated until the system releases itself If further errors occur contact LION If the mains electricity cable of the standard M Fire console is to be repaired or replaced use a 3 core rubbe...

Страница 8: ...1A T Standard M Fire console Operation console upon which the gas cylinder is placed Dimensions width x depth x height 40 5 x 47 x 103 cm Weight excluding gas cylinder 33 kg Connection cable for mains power 4 m rubber flex 3g1 HO7RN Gas hose to combustion tank 7 5 m Connection flex to combustion tank 7 5 m Connection flex for remote control 7 5 m optional operation of start button Burner units M F...

Страница 9: ...ition and flame detection Close the gas valve on the gas cylinder after every use The standard M Fire control console must be disconnected from the burner unit before transport The gas bottle should preferably be transported separately The M Fire Unit may only be opened and repaired by professionally trained personnel Connect the system to a properly earthed mains connection in accordance with cur...

Страница 10: ...n 1 2 14 01 20 Page 9 Version 1 2 14 01 20 LION Protects B V Industrieweg 5 5111 ND Baarle Nassau the Netherlands T 31 0 13 507 6800 F 31 0 13 507 6808 E infoEMEA lionprotects com WWW LIONPROTECTS COM LION Group Inc All rights reserved ...

Отзывы: