M-Fire Units
User’s Manual
Version 1.2 | 14/01/20
Page 6
The standard M-Fire console requires no special maintenance.
However, the battery should be kept
charged.
If the battery is empty, it should be recharged immediately by connecting the control panel to
the mains electricity and pulling out the emergency stop switch. The console may remain connected to
the mains once the battery is fully recharged.
Resolving faults
Check the gas hoses condition
before each use
. If leaks are detected, immediately turn off the gas
supply and ensure that repairs are carried out.
An internal fault in the electronics is indicated by the rapid blinking of the 'Fail' LED for as long as this fault
is unresolved. Operation is not possible!
In cases of overheating in the flame detection sensors, the 'Fail' LED will flash until the temperature has
returned to normal. Operation is not possible!
If the start button is pressed during the occurrence of an error, an acoustic signal will be sound (fast
beeping) for as long as the button is pushed in.
In cases of overheating, a waiting period is activated until the system releases itself.
If further errors occur, contact LION.
If the mains electricity cable of the standard M-Fire console is to be repaired or replaced, use a 3-core
rubber flex with a core diameter of 1 mm
2
and the specification H07RN-F.
Guarantee
•
LION will replace any part of the “M-Fire Unit” in case the malfunctioning is a result of a material or
construction fault, within 12 months after the original purchase date.
•
LION will not take any responsibility for any damage caused by using or defects concerning the “M-
Fire Unit.”
•
In case of defects or damages, in which has been established that the operating and maintenance
instructions have not been followed, or, as a result of rough and / or unjustified handling, any claim
regarding to LION will be denied.
•
The warranty will be invalid when using powder extinguishing agents.