                                                                                                                          Shenzhen Linshang Technology Co., Ltd. 

9-7-2020  Page  1  of  6 

 

 

 

 

 

 

LS108A/LS108D 

Lens Transmission Meter 

(2nd) 

User Manual V9.0 

 

 

 

 

 

 

 

 

 

 

Please read this manual carefully before using and reserve it for reference. 

 

Note

: Test hole diameter: LS108A is 1mm, LS108D is 0.5mm 

 

 

Содержание LS108A

Страница 1: ...nology Co Ltd 9 7 2020 Page 1 of 6 LS108A LS108D Lens Transmission Meter 2nd User Manual V9 0 Please read this manual carefully before using and reserve it for reference Note Test hole diameter LS108A is 1mm LS108D is 0 5mm ...

Страница 2: ... 1 5 Measurement accuracy 2 colorless and uniform transparent material 0 90 transmission 6 Display 480 270 dot matrix color screen 7 Power input DC5V 1A 8 Dimensions 170mm 180mm 144mm L W H 9 Weight about 1570g III Operation 1 Power on self test Power on Plug in the power supply and ensure there is no test sample under testing Short press the button to turn on the meter The boot interface displays...

Страница 3: ...ace will switch to English Short press button to confirm the setting and return to the Setup interface B Select Display Item Take the English as an example short press button to enter the setting item you selected Short press the Operation button to select 850nm 550nm 940nm 550nm 850nm 550nm 940nm Select 850nm 550nm 940nm the measurement interface displays the 850nm infrared transmission 550nm vis...

Страница 4: ... the setting mode and enters into the measurement mode 3 Measurement and operation After powering on the meter enters into the measurement interface all transmission data is displayed as 100 The test sample is placed on the test hole the LCD screen displays the visible light of 550nm infrared light of 940nm and 850nm of the test sample As shown in the figure below The infrared transmission of 850n...

Страница 5: ...he appropriate power supply IV Features 1 Brand new wavelength synthesis technology measure transmission data of 3 wavelength simultaneously 2 Obtain the visible light transmission of 550nm infrared light transmission of 850nm and 940nm at the same time by aligning the test hole just once which greatly improves the test efficiency 3 The test hole has an alignment indicator LED which is used to hel...

Страница 6: ...use please turn it off 5 When the interface displays abnormal voltage please replace the power supply VI Standard Packing List No Description Quantity Unit 1 Lens Transmission Meter 2nd 1 set 2 User manual 1 pcs 3 Certificate warranty card 1 pcs 4 DC5V adapter 1 pcs 5 PC software U disk 1 pcs 6 USB extension cable 1 pcs VII Service 1 The meter has one year warranty If the meter works abnormally pl...