background image

Pipe Pump L3 / Pipe Pump stationary 

 Operating Instructions  

(Translation of the operating instructions) 

 
 
This user information should be read and observed before installation and use of the 
apparatus supplied.

 

The water pumpe has been manufactured to support water. Any other use is absolutely 
prohibited. 
Before operation, examination by a qualified technician should take place to ensure that 
necessary electrical precautions are available.  An electrical fault switch (FI) with a 
nominal current of up to 30mA is stipulated.  The voltage displayed on the label of the 
apparatus must agree with that of the mains voltage.  Standard models are delivered 
completely sealed and ready for use.  All apparatus are equipped with a motor 
(overheating) protector (either by a motor protection device attached to the cable end or 
by a heat sensor inside the motor itself).  If you have received apparatus without motor 
protection or with a free cable end, then a qualified technician should install the motor 
protector and/or attachment before operation.

 

 
Before connecting the pump to the mains, please ensure that no one remains in the water.  
Working on the pump while in the water (in particular, swimming to the apparatus or 
clambering onto the aerator) is strictly prohibited on the grounds of safety.  Warning! Injury 
risk!  Touching of the pump while in operation is prohibited.

 

 
Warning – Please ensure that the plug connection is dry when you connect it to the mains.

 

 
It may happen that in the case of 400V models, the direction of rotation of the motor is 
incorrect.  This is immediately recognisable.  In such cases, a qualified electrician can 
transpose two of the poles in the plug.  The plug must of course be removed from the plug 
socket beforehand.

 

 
Maintenance

 

All pumps supplied require little or no maintenance.  From time to time simply clean all 
parts of the apparatus.  To do this you must remove the apparatus from the water.  
Warning – first disconnect from the mains! 
 
If the apparatus is supplied with a screen, this, in particular, should be kept clean. A 
perfect functioning of the apparatus can only be assured if the surface of the screen is 
clean.

 

 
At least once a year, the apparatus should be examined for perfect running of the 
propeller and, in the case of submersible motors, for the condition of the motor’s 
watertight flanges.  If you experience any problems, please contact us.

 

 

Further Information

 

We would advise you that, in accordance with product liability law, we do not accept 
liability for damage caused by our apparatus, if the information and advice given within 
these operating instructions has not been followed.

 

 
The aerator should never be pulled, carried or fixed into place, by the connection cable.  
Only suitably qualified persons should carry out replacement of the connection cable.   
The connection lead should be no lighter than a rubber hose HO7 RN-F (EN 60335-2-41).  
Avoid wear and tear on the connection cable!

 

 
The electric lead should be kept in an area where there is no risk of flooding and should 
be protected from damp.  Connection cable and plug should be examined for damage 
before use. 
 
The pipe pump L3 should not be operated out of water!  
In the event of aerator defects, repairs should be carried out only by the manufacturer or 
by an authorised dealer.  In addition, only original spare parts should be use 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 