manualshive.com logo in svg
background image

LINN

IKEMI

 

&

 

GENKI

 

C D   P L A Y E R   O W N E R S   M A N U A L

Содержание GENKI

Страница 1: ...LINN IKEMI GENKI C D P L AY E R O W N E R S M A N U A L...

Страница 2: ...Linn software is or will be Year 2000 Compliant or that Linn s software will be Year 2000 Compliant if used in conjunction with non Linn products systems or software The Purchaser Installer Retailer o...

Страница 3: ...SE WITH SAME TYPE AND RATING ATTENTION UTILISER UN FUSIBLE DE RECHANGE DE M ME TYPE DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE ATTENTION DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE...

Страница 4: ...nd a third grounding prong The wide blade or the third prong are provided for your safety When the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete ou...

Страница 5: ...dangerous if engaged in a live socket c Only fit a 13 Amp BS1363A approved plug with a 5 Amp fuse d The cable wire colours or a letter will be marked at the connection points of most quality plugs Att...

Страница 6: ...1994 Absorbed emissions EN60555 2 1987 Harmonics EN60555 3 1987 Voltage fluctuations EN55020 1994 Immunity FCC notice NOTE This equipment has been tested and found to comply with the limits for a Cla...

Страница 7: ...GENKI 12 Using the front panel 12 Using the handset 14 Switching on and off 15 Display information 16 Playing a disc 17 Skip and search 18 Direct track number selection 19 Repeat play 20 Programming 2...

Страница 8: ...Microsonics are either registered trademarks or trademarks of Pacific Microsonics Inc in the United States and or other countries HDCD system manufactured under license from Pacific Microsonics Inc Th...

Страница 9: ...he latest Linn CD players Both products are covered in this manual as they share many common attributes If you just want to play music now skip to the section on Using the Ikemi and Genki If you would...

Страница 10: ...riable output allows a complete CD playing system to be built with only a power amplifier and loudspeakers The Ikemi exceeds the audio performance of our previous best CD player and external D A conve...

Страница 11: ...immunity to external disturbances The digital audio signals from this CD engine are connected through very short links to the audio module which contains our 2D digital signal processing algorithm the...

Страница 12: ...t microprocessor on the control module behind the front panel The operating software is held in flash memory which is loaded when the product is built through the optional RS232 interface module The R...

Страница 13: ...xisting digital filters so every CD benefits Digital outputs The Ikemi and Genki both have low jitter SPDIF digital audio outputs on BNC sockets The Ikemi also has an optical output Toslink and an AES...

Страница 14: ...udio data at the rate the master clock in the DAC requires The DAC therefore becomes the master and the CD transport the slave There are other systems which try to achieve this goal but they invariabl...

Страница 15: ...layer at a later date WARNING Do not connect the mains supply until you have verified that the CD player is set to the correct voltage for your mains supply The IKEMI and GENKI are factory set for a 2...

Страница 16: ...eft of the voltage selector Disconnect the mains supply by removing the IEC mains cable from the mains inlet module Using a flat blade screwdriver remove and replace the fuse If the fuse blows a secon...

Страница 17: ...fiers Locating the IKEMI and GENKI for use with the handset The Linn infra red remote control system is exceptionally sensitive and you should be able to operate your CD player with the handset from a...

Страница 18: ...mage IKEMI Analogue outputs The Ikemi has two identical pairs of single ended RCA phono socket outputs Use one to connect to your main control amplifier and one for connection to other components for...

Страница 19: ...tputs Use one pair of the fixed level outputs if you already have a high quality control amplifier The other fixed output can be used to connect to other components for example a multiroom distributio...

Страница 20: ...use The front panel display gives clear information about what you are doing and although there are many sophisticated features all the most commonly used ones require only one or two key presses The...

Страница 21: ...E RANDOM PLAY REPEAT PLAY DISPLAY MODE SEARCH FORWARD SKIP BACK SKIP FORWARD STOP OPEN CLOSE PAUSE PLAY DISPLAY SEARCH BACKWARD VOL VOL M BAL L BAL R 8888 CD CA MUTE HDCD INDEX DIGITAL TRACK TIME TRAC...

Страница 22: ...ows the function of each group of keys Note that the number keys operate the CD or tuner depending on which one was last controlled by the handset If the number keys appear not to work press one of th...

Страница 23: ...GENKI The illustrations show the IKEMI front panel A small insert shows the appropriate remote control handset button to operate both the IKEMI and GENKI The features unique to the GENKI are covered...

Страница 24: ...e and balance displays Display Description Example TRACK INDEX Track and index number No disc present 00 Disc is playing 3 1 Disc is stopped 16 TRACK TIME Time from the start of 0 38 the current track...

Страница 25: ...PAUSE To continue playing press PAUSE again or PLAY Press STOP When stopped the display shows the number of tracks on the disc RND RPT DIS 00 CD CA INDEX DIGITAL TRACK TRACK RND RPT DIS 1 1 CD CA IND...

Страница 26: ...w the disc time RECORD RECORD RND RPT DIS 8601 CD CA MUTE HDCD INDEX DIGITAL TRACK TIME TRACK REMAIN TOTAL REPEAT VOLUME BALANCE RND RPT DIS 8501 CD CA MUTE HDCD INDEX DIGITAL TRACK TIME TRACK REMAIN...

Страница 27: ...button on the handset to tie the numbers to the CD player To select a two digit track number press the first digit and hold for two seconds 1 Press the second digit The selected track will play immed...

Страница 28: ...of section repeat Press Repeat a third time to cancel all repeats RECORD RECORD RECORD RND RPT DIS 8381 CD CA HDCD INDEX DIGITAL TRACK TRACK REPEAT VOLUME RND RPT DIS 8581 CD CA HDCD INDEX DIGITAL TR...

Страница 29: ...andset select the first track to play Press DIS DISPLAY to save this programme step Using SKIP or the handset repeat for all chosen tracks then press PLAY Open the drawer to clear the programme RND RP...

Страница 30: ...rack to exclude Press DIS DISPLAY to save this programme step Using SKIP or the handset repeat for all chosen tracks then press PLAY Open the drawer to clear the programme RECORD RECORD RECORD RND RPT...

Страница 31: ...REMAIN TOTAL REPEAT VOLUME BALANCE GENKI variable output Increase and decrease volume Move the balance to the left Move the balance to the right Mute the variable output RECORD RECORD VOLUME VOL VOL M...

Страница 32: ...ing The play list takes several seconds to create please wait Intro play mode This will play the first ten seconds of each track on the disc in sequence Press PLAY to listen to the selected track Inde...

Страница 33: ...omise the operation of the IKEMI and GENKI go to the User Options mode Switch the power on while holding the OPEN button for twelve seconds OPEN selects the Option STOP changes its value See the follo...

Страница 34: ...wer up U4 CD status at power down 0 do not retain status stopped paused playing 1 retain status track number U5 Default volume on power up 0 Volume 25 1 Volume 50 U6 Volume on power up is last 0 Use v...

Страница 35: ...a soft cloth from the centre of the disc outwards Dampen the cloth for more persistent marks then dry with a soft cloth Storage Don t leave discs in the player If they re not being played put them bac...

Страница 36: ...41 307 7777 fax 44 0 141 644 4262 UK helpline 0500 888909 email helpline linn co uk website http www linn co uk Linn Incorporated 4540 Southside Boulevard Suite 402 Jacksonville Florida 32216 phone 1...

Страница 37: ...n 3 cold SPDIF electrical BNC 0 5V pp 75 Ohms SPDIF optical TOSLINK AES EBU electrical XLR male 1V pp 110 OHMS pin 1 gnd pin 2 hot pin 3 cold Sync Link input RCA phono 0 10 Vdc 10k Ohms Linn use only...

Страница 38: ...ote in out RCA phono 4mA na Knekt use only Mains input IEC 90 130Vac 180 260Vac manual switch 20 Watts max Dimensions 80mm H x 320mm W x 325mm D 3 15 x 12 6 x 12 8 inches Weight 3 3kg 7 26 lb RS232 op...

Страница 39: ...PACK 169...

Отзывы: