7 Storage, transport, installation altitude
7 Lagerung, Transport, Aufstellhöhe
Sliders are to be stored and transported only in the plastic containers (with cardboard inlay)
provided for this purpose, or already installed and secured in LinMot P stators.
Remove the slider from this plastic containers only for assembling.
The storage area must be dry, dust-free, frost-free and vibration-free.
Prescribed storage temperature: -
15 °C…70 °C
The motor must be protected against extreme weather conditions.
The air in the storage area must not contain any harmful gases.
The max. installation altitude is 4'000 m above sea level.
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
LinMot Läufer dürfen ausschliesslich in der Orginalverpackung transportiert und gelagert
werden.
Die Läufer sollten erst beim Einbau aus der Verpackung genommen werden.
Der Lagerraum muss trocken, staubfrei, frostfrei und erschütterungsfrei sein.
Vorgeschriebene Lagertemperatur: -
15 °C…70 °C
Der Motor muss vor extremen Witterungen geschützt werden.
Die Raumluft darf keine aggressiven Gase enthalten.
Die maximale Aufstellhöhe beträgt 4'000 m ü. M.
Ab 1'000 m ist bei Luftkühlung ein Derating von 1 °C pro 100 m zu berücksichtigen.