E1400 V2 Installation Guide
7.8 X33
X33
Safety Relays (only with the -1S option)
4 / 8
3 / 7
2 / 6
1 / 5
Ksr +
Ksr -
Ksr f+
Ksr f-
Safety Relay 1 / 2 Input positive
Safety Relay 1 / 2 Input negative
Safety Relay 1 / 2 feedback positive
Safety Relay 1 / 2 feedback negative
Spring cage connector
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm2 (AWG 16)
- Stripping length: 10mm
- Never connect the safety relays to the logic supply of the drive!
7.9 X7 – X8
X7 - X8
CMD (RS485/CAN)
1
2
3
4
5
6
7
8
case
R
A
RS485_Rx-
B
R
Y
GND
GND
RS485_Tx-
Z
CAN_H
CAN_L
Shield
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in RS485 and CAN terminations can be activated by S5.2 and S5.3.
X7 is internally connected to X8 (1:1 connection)
7.10 X9
X9
PROFIBUS DP (only available on E1430-DP-QN)
1
6
2
7
3
8
4
9
5
case
Not connected
+5V
(isolated)
Not connected
Not connected
RxD/TxD-P
RxD/TxD-N
CNTR-P
Not connected
GND
(isolated)
Shield
DSUB-9 (f)
Max. Baud rate: 12Mbaud
NTI AG / LinMot
®
www.LinMot.com
Page 13/27