7.7 Flash Card (FC)
A micro SD card can be used in socket M1 “Memory Card”. The flash card must be a type provided by LinMot. Other
flash cards are not supported. The following flash card is available for the C1251-2S drives.
Accessories
Description
Article Number
FC10-000
Flash Card for Safety Drives
0150-2936
Table 30: Flash Card List
The FC is used for drive exchange in the field, without the use of LinMot-Talk. The FC is used to save and reload drive
configurations. The configurations are CRC protected.
The access to the flash card by unauthorized persons must be limited by the end user.
The FC commands are activated by the ID switches S1/S2 and the safe address switches S11/S12. The next tables give
an overview. The detailed behavior is described in the following subchapters.
S1/S2 Positions
Commands
S1 (5..8): Bus ID High (0 … Fh). Bit 5 is the LSB, bit 8 the MSB.
S2 (1..4): Bus ID Low (0 … Fh). Bit 1 is the LSB, bit 4 the MSB.
FFh
Default all parameters:
Sequence:
FFh --> Reboot --> 00h --> Default all parameters (safe and non-safe) --> Reboot (user action)
FEh
Set IP configuration mode to DHCP. Not used for C1251-2S drives.
FDh
Saves the complete configuration to the FC. There are written two files, one for the non-safety configuration,
the other for the safety configuration.
The file name for the non-safety configuration is generated from the parameter 03E8h «Drive Name»:
“Config_” + 03E8h + “.pvl”
The file name for the safety configuration is generated from the parameter 4780h, «FS Config Name»:
“SafetyConfig_” + 4780h+ “.lsc”
Sequence:
FDh --> Reboot --> 11h --> Save the complete configuration
FCh
Load non-safety configuration from the FC.
The file “Config_*.pvl”is loaded (see command FDh).
Remark: Only one file must be on the FC, otherwise the selection is not clearly.
Sequence:
FCh --> Reboot --> 22h --> load non-safety configuration
F0h - FBh
Reserved for future function
Table 31: Commands called by ID switches S1/S2
2S Drive Systems / 0185-1174_E_1V1_SM_C1251-2S / NTI AG
0185-1174_E_1V1_SM_C1251-2S / 2021-11-26 16:43 (Rev. 12500)
Page 64 of 150